ii <br /> through. Delays in reimbursement from the UST Fund had exhausted available financial <br /> resources. <br /> 90 All Monitoring Wells were sampled on March 9, 2010. <br /> Monitoring Wells MW-10 was installed on 7/12/10 and MW-11 was installed on 7/13/10. <br /> On 10/4/10 the remaining request for reimbursement was approved for payment and funds have <br /> 95 since been received. <br /> Monitoring well MW-2 casing was trimmed on 3/31/11 and new elevation data collected on <br /> 6/2/11. <br /> 100 On 5/5/11 the EDH issued direction to re-start the pump and treat system and to provide an <br /> evaluation of the Granular Activated Carbon (G.A.C.) treatment system. Foothill Engineering <br /> recommended augmenting the G.A.C. with a bio-reactor on 6/28/11. Foothill Engineering is <br /> awaiting approval of the bio-reactor prior to restarting the pump and treat system. <br /> 105 This site is on a modified sampling schedule the 3/23/12 sampling is the bi-annual all well <br /> sampling event. On 3/23/12 the well pump was removed because the suspension chain had <br /> rusted through and instilled serve distortion in the piping making it unsafe to operate. <br /> 110 REPORT OF FINDINGS FOR THE FIRST QTR 2012 MONITORING EVENT <br /> The groundwater pump and treat system was shut down on 2/7/09. A modified monitoring <br /> schedule has been approved by San Joaquin County EHD in order to stay in compliance with the <br /> State of California requirements. This is the high water monitoring event for 2012 as required by <br /> 115 the END letter of March 5, 2009 and modified by the May 5, 2011 letter. This sampling event is <br /> the bi-annual all well monitoring event. <br /> 2. PROCEDURE <br /> On March 23, 2012 Del Tech Geotechnical Support Services extracted water samples from all <br /> 120 wells. The work was supervised by Foothill Engineering. Foothill Engineering also removed the <br /> pump from EW-1 since the suspension chain had rusted through and instilled serve distortion in <br /> the piping making it unsafe to operate. <br /> All wells were sounded for depth to water prior to disturbance. All wells were sampled using the <br /> 125 tube with check valve pump system. MW-2R, and MW-3R were purged at 0.25gpi-n. MW-1, <br /> MW-IR,and MW-3 were purged at 0.5gpm. MW-2, MW-5, MW-6, MW-7S, MW-8S, MW-8D, <br /> MW-9, MW-10 and MW-11 were purged at I.Ogpm. EW-1 was purged at 3.Ogpm. The wells <br /> were purged for three casing volumes and sampled for analysis. The physical properties of the <br /> groundwater can be found in the Del-Tech Field Report, which is in Exhibit E. <br /> 3 of 82 <br />