Laserfiche WebLink
i� <br /> a <br /> APPENDIX F <br /> Monitoring and Sampling Procedures <br /> STALLWORTH AUTO SALES <br /> 602 North California Street, Stockton , California <br /> STATIC WATER LEVEL MEASUREMENTS <br /> Before sampling and during groundwater monitoring , static water levels are measured <br /> using an electric water level indicator. Water level data is recorded to the nearest 0. 01 -foot <br /> 1 from a reference point marked on the top of the PVC well casing . <br /> 1 <br /> WELL EVACUATION <br /> Subsequent to measurement of depth to water and prior to sampling , each well is purged <br /> to ensure samples are representative of the formation , rather than standing water in the <br /> well casing . Wells are purged using a Waterra inertia pump and dedicated %-inch plastic <br /> tubing or disposable polyethylene bailers . <br /> Wells are purged until a minimum of three casing-water volumes are removed from the well <br /> and/or the field-measured ground water parameters (pH , temperature , and conductivity) <br /> are stabilized . However, if a well is purged dry prior to evacuating three casing volumes , <br /> a sample is collected following 80 percent recovery of ground water within the well , or after <br /> a minimum of one hour, but within eight hours, of well evacuation . Field data and logs are <br /> provided in Appendix C. <br /> SAMPLE WITHDRAWAL <br /> Water samples are collected from each monitoring well using an inertia pump with <br /> dedicated plastic/Teflon tubing or disposable polyethylene bailers; plastic tubing used with <br /> the inertia pump is either dedicated to each well point or changed at each sampling event, <br /> thereby minimizing cross contamination due to sampling devices. Samples are drawn and <br /> collected in such a manner that agitation and exposure of the groundwater to the <br /> atmosphere is minimal . <br /> SAMPLE HANDLING <br /> Groundwater samples are collected into laboratory-supplied 40-ml volatile organic analysis <br /> (VOA) vials without preservative and one 1 -liter amber bottle; samples are collected with <br /> no visible air bubbles present in the VOAs after filling and capping . Following collection , <br /> samples are appropriately labeled , placed on ice, and kept in a cooler until delivered to Cal <br /> Tech Environmental Laboratories (CTEL), a State of California Department of Public <br /> Advanced GeoEnvironmental, Inc. <br />