WALL TYPE LEGEND
<br /> SYMBOL DESCRIPTION
<br /> NEW WALL CONSTRUCTION X X
<br /> EXISTING WALL CONSTRUCTION `
<br /> WALL CONSTRUCTION TYPES
<br /> 11WEXISTING EXTERIOR PEMB METAL WALL FRAMING WITH 5/8"GWB TO UNDERSIDE OF
<br /> DECK. FINISH PER FINISH SCHEDULE SHEET A1.4.
<br /> 17 PARTITION WALL:6"-20 GA.METAL STUDS AT 16"O.C.TO UNDERSIDE OF DECK
<br /> WITH ONE LAYER 1/2"GWB EACH SIDE TO 6"ABOVE FINISH CEILING ON SALES
<br /> SIDE AND OFFICE SIDE,TO 8'-0"A F.F.ON TOILET SIDE,AND TO UNDERSIDE OF
<br /> DECK ON STOCKROOM SIDE.PROVIDE MOISTURE RESISTANT GWB IN TOILET p
<br /> AREAS,FINISH PER FINISH SCHEDULE ON SHEET A1.4. 1 Z 3 4 5 6 7 8
<br /> PARTITION WALL:6"-20 GA.METAL STUDS AT 16"O.C.TO UNDERSIDE OF DECK
<br /> WITH ONE LAYER OF 1/2"GWB EACH SIDE TO 8'-0"A F.F.ON TOILET SIDE,AND TO
<br /> UNDERSIDE OF DECK ON STOCKROOM SIDE. PROVIDE MOISTURE RESISTANT GWB
<br /> IN TOILET AREAS AND BEHIND MOP SINK,FINISH PER FINISH SCHEDULE ON SHEET
<br /> A1.4.
<br /> 4 PARTITION WALL:3 518"-20 GA.METAL STUDS AT 16"O.C.TO 84"A.F.F.WITH ONE
<br /> LAYER OF 1/2"GWB EACH SIDE TO 8'-0"A.F.F.ON TOILET AND OFFICE SIDE,AND TO 6" - -----
<br /> ABOVE FINISH CEILING ON HALLWAY SIDE. PROVIDE MOISTURE RESISTANT GWB IN
<br /> TOILETAREAS, FINISH PER FINISH SCHEDULE ON SHEETA1.4,
<br /> EXISTING EXTERIOR WALL:EXISTING PEMB METAL WALL FRAMING,PROVIDE 3 5/8" 5
<br /> METAL STUD FURRING TO TOP OF STOREFRONT WITH ONE LAYER 5/8"GWB ON 8 5
<br /> EXPOSED SIDE TO 12'-0"A.F.F.ALIGN WITH EXISTING GWB AND FINISH PER FINISH 1 1 1 0 0
<br /> SCHEDULE ON SHEET AIA 76 ] 7
<br /> EXISTING EXTERIOR STOREFRONT:EXISTING PEMB METAL WALL FRAMING,PROVIDE 3 5/8" — o
<br /> :J7
<br /> METAL STUD FURRING TO TOP OF STOREFRONT WITH ONE LAYER 5/8"GWB ON EXPOSED
<br /> 00
<br /> SIDE TO TOP OF STOREFRONT ON OFFICE SIDE AND TO FINISH CEILING ON TOILET SIDE.
<br /> ALIGN WITH EXISTING GWB AND PROVIDE MOISTURE RESISTANT GWB IN TOILET AREAS, ( w -- .� ,_ „ —' —' —. `— — —' — — — � — —
<br /> 1'
<br /> FINISH PER FINISH SCHEDULE ON SHEET A1,4, _2" 8 �-
<br /> U
<br /> 17 PARTITION WALL:3 5/8'-20 GA.METAL STUDS AT 16"O.C.WITH ONE LAYER OF 112"
<br /> GWB ON EXPOSED SIDE TO 6"ABOVE FINISH CEILING ON SALES SIDE.ALIGN WITH
<br /> FACE OF EXISTING COLUMN AND FINISH PER FINISH SCHEDULE ON SHEET A1.4.
<br /> GENERAL NOTES , , , F-
<br /> 1. ENERGY CODES AND THE APPLICATION OF ENERGY CODES VARY PROJECT SITE TO 1 I 10 =%
<br /> PROJECT SITE.IT IS THE RESPONSIBILITY OF THE LL TO DETERMINE THE IMPACT OF THE -�Oo
<br /> GOVERNING ENERGY CODES ON THE PROTOTYPICAL DESIGN, INCLUDING THE 2 c
<br /> IMPLEMENTATION OF AN ENTRY VESTIBULE WHEN REQUIRED. ( 1 w -
<br /> 2. AT GYPSUM BOARD INSTALL VERTICAL CONTROL JOINTS AT 20'-0"O.C.(TYP)ALIGN WITH -� -- -+ •+
<br /> COLUMN LINES WHERE POSSIBLE. I 189'x"
<br /> 3. DEVELOPER/G.C./LANDLOARD MUST USE THE FDS SUPPLIED FINAL"FLP"PLAN SHEET FOR
<br /> THE PURPOSES OF DIMENSIONAL AS-BILT SUBMITTAL TO FAMILY DOLLAR. 140'-5" 28'-0"
<br /> 4, NO PLUMBING OR CONDUITS SHALL PASS UNDER THE SALES FLOOR EXCEPT AT THE TOILET, LOCATION OF NEW ROOF rn $ ¢ a m
<br /> OFFICE,SALES,SUPPORT,AND WASTE LINE AT COOLER LOCATION. (
<br /> ACCESS HATCH AND o
<br /> 5. GENERAL CONTRACTOR TO PROVIDE INSECT/TERMITE TREATMENT PER BONDED AREAS IN SQ JARE FEET: SALES AREA „ LADDER;SEE SHEET 6.0
<br /> (WARRANTED)AUTHORIZED INSTALLING SUBCONTRACTOR AND LL IS TO FORWARD PROOF EXT. GROSS= 10,006 SO FT f $_1 FOR DETAILS. m
<br /> OF SAME TO FDS. INTERIOR NES (PAINT TO PAINT): 101 I 6 y aUi .m
<br /> 6. IF LOCAL CODES REQUIRE A FIRE ALARM SYSTEM TO BE INSTALLED A LICENSED ENGINEERSATES AREA =8,604 99 FT 4 STOCK ROOM D ET v
<br /> SHALL PROVIDE LIFE SAFETY DRAWINGS SHOWING LOCATION AND ELEVATION OF ALL 4 VESTIBULE/ ICE = 100 3Q FT 2 1
<br /> EQUIPMENT. A2.0 i 106 A2.0 NnNNn
<br /> 1 ( SALES SUPPORT = 1,302 SQ FT ® 2 TONT 3
<br /> 7. THIS STORE WILL HANDLE PREPACKAGED FOOD/BEVERAGE ITEMS ONLY. ry1�I
<br /> LE
<br /> 8. NO SALE AND DISPLAY OF UPHOLSTERED FURNITURE PERMITTED. 3 A5.0 4
<br /> 104
<br /> 9. PROVIDE 10"H X 7"W ALUMINUM SIGNAGE AT EVERY ENTRY POINT ON EXTERIOR WALL INTO 0
<br /> THE BUILDING STATING:"THIS IS A TOBACCO FREE CAMPUS FOR THE HEALTH OF OUR 6 3'-0"W X T-0"M GWB A
<br /> EMPLOYEES,VENDORS AND VISITORS SMOKING IS NOT PERMITTED ON THIS CAMPUS THIS TRIMMED OPENING4 0 ° ,
<br /> INCLUDES ALL BUILDINGS,PARKING LOTS AND GROUNDS."SIGNS MAY BE FOUND AT 0 I 3/4"SOL D CDX BOARD UP ARCHITECTS, INC.
<br /> WWW.COMPLIANCESIGNS.COM TO 4'-0" .F.F,;ATTACH TO
<br /> 10, G.C.SHALL PROVIDE KEY BOX FOR LOCK ACCESS DURING PUNCHOUT AND TURNOVER. 9 „ 4 HALL o RACKIN 17710 Detroit Avenue
<br /> COMBINATION TO MATCH LAST FOUR DIGITS OF STORE NUMBER. 8'-1 0 103 4 A,� 5 Lakewood, Ohio 44107
<br /> 11. IF A KNOX BOX ENTRY SYSTEM IS REQUIRED BY THE CODES GOVERNING THE PROVIDE A SIGN AT ENTRY DOOR(S)THAT IS VISIBLE DURING Phone (216) 521-5134
<br /> CONSTRUCTION OF THE PROJECT,THE RECESSED KNOX BOX SHALL BE PROVIDED BY THE ,r BUSINESS HOURS."THIS DOOR IS TO REMAIN UNLOCKED I 0 I Fax(216)521-4824
<br /> G.C.PRIOR TO THE COMPLETION OF THE PROJECT LOCATE PER LOCAL CODE I `- WHEN BWILDING IS OCCUPIED.”SIGN SMALL CONSIST OF ONE FIC 2 3 Www.adaarchitects.cc
<br /> REQUIREMENTS.KNOX BOX CONTACT-866.625.4563 INCH(1")MIGH BLACK LETTERS MOVNTED AT 5'4"A.F.F.AND _ \ WOM N
<br /> IE
<br /> 12. THE INTERIOR FINISHED WALLS OF THE SALES AREA MUST BE FLUSH WITH NO " SIGN SMALLL BE PLACED ON THE EGRESS SIDE OF DOOR. Q' 102 TOIL T EMPL
<br /> OBSTRUCTIONS OR PROJECTIONS WITH EXCEPTIONS TO COLUMNS AT EACH SIDE OF THE 1 3-4 3 6',4" 10 ( 105 19 1O 95E9 cl AR�y
<br /> STOREFRONT WHICH ARE TO BE FURRED OUT AS SHOWN. — — ,— — _ _ _,
<br /> 6 6 107 XTF
<br /> 13, FOR WALL TYPES RE:A8.0;FOR DOOR TYPES RE:A7.0 11 11 7 11 7 ROB J.
<br /> 14, ALL PROJECTS SHALL BE 12"ABOVE 100 YEAR FLOOD PLAN(FINISH FLOOR ELEVATION). - - - - -- - - - - - - - - - - - - -- - - - - - _ _ - - - -- -- - - - - - - - - - - -- -- — - - - — — — - - - - - - - -- - - - - - - - - — _ _ AC
<br /> 15. G.C. IS ADVISED THAT IS THEIR RESPONSIBILITY TO ENSURE THAT ALL CONSTRUCTION IS IN
<br /> COMPLIANCE WITH ALL LOCAL,STATE,AND NATIONAL CODES GOVERNING THE N -32106
<br /> CONSTRUCTION AND WITH THE AMERICANS WITH DISABILITIES ACT.G.C.IS TO VERIFY TME NEW STOREFRONT DOOR,G.C.TO ENSURE
<br /> � � EMERGENCYEGRESS HARDWARE ISPROVNED. 1 August 31, 2019
<br /> COORDINATION OF THE VARIOUS DRAWINGS, IF A CONFLICT OF INFORMATION IS FOUND,G.C. 3 S RENEWAL DATE
<br /> SHALL CONTACT THE REQUIRED PARTIES PRIOR TO PROCEEDING.
<br /> 16. SALES SUPPORT AREA:NO HIGH PILED STORAGE,AS DEFINED PER CURRENT FIRE CODE:NO ATF OF CA�����
<br /> STORAGE GREATER THAN 12'-0"A.F.F. NO HIGH HAZARD COMMODITIES ABOVE 6'-0"(TYP) �— —_ —� �. _ — - — -------- -- — - — — 03/09/18
<br /> 17. THIS PLAN SHOWS ALL SPECIAL ELECTRICAL REQUIREMENTS.THE LOCATIONS INDICATED _ _ ___ _ _ _ __ _ _ _ _ ____ ___ _ __ _ _ _ ___ _
<br /> ON THE PLAN ARE APPROXIMATE.THE G.C./SUBCONTRACTOR SHALL BE IN RECEIPT OFA
<br /> FINAL SITE DOLLAR STORES FOR COMPLETION OF ELECTRICAL WORK.
<br /> 18. ELECTRICAL LOCATIONS MUST BE VERIFIED BY THE FAMILY DOLLAR STORE PROJECT
<br /> MANAGER,PRIOR TO INSTALLATION.
<br /> DESIGNER NOTE:
<br /> NO EXCEPTIONS NOTE:
<br /> THE INTERIOR FINISHED WALLS OF THE SALES AREA MUST BE FLUSH WITH NO OBSTRUCTIONS OR
<br /> PROJECTIONS WITH EXCEPTION TO COLUMNS AT EACH SIDE OF THE STOREFRONT WHICH ARE TO I I J
<br /> BE FURRED OUT AS SHOWN. I I J rn
<br /> Lu
<br /> 86'4"X 88'-1}"ARE THE MINIMUM REQUIRED FINISHED DIMENSIONS OF THE SALES FLOOR.CHANGES N = U
<br /> TO THE EXTERIOR BUILDING MATERIAL OR STRUCTURAL ELEMENTS WILL REQUIRE TME BUILDING BEA I ® cn Al
<br /> ENLARGED TO MAINTAIN THE MIN. INTERIOR CLEAR DIMENSIONS. VAN Q
<br /> Q W
<br /> W
<br /> FINISHED FLOOR ELEVATION Z z
<br /> ALL PROJECTS:SHALL BE 12"ABOVE 100 YEAR FLOOD PLAIN. Q
<br /> Z
<br /> z
<br /> SALES SUPPORT NOTE: O z
<br /> NO HIGH PILED STORAGE PER 2006-IFC 2302 OR 2012-IFC 3202,NO STORAGE GREATER THAN 12FT. W UQ a
<br /> NO HIGH HAZARD COMMODITIES ABOVE 6FT. / W O
<br /> Q0
<br /> Li CD
<br /> DESIGNER NOTE: M N LL
<br /> SWING LOADING DOOR TO OPEN TOWARDS LOADING AREA
<br /> � ARCHITECTURAL FLOOR PLAN
<br /> KEYED NOTES: aD -
<br /> A1.0 SCALE: 1/8" = 1'-0" o m
<br /> FACES LOADING AREA O DESIGNERS TO COORDINATE LOCATION OF WATER VENDING O4 EXISTING ELECTRICAL SERVICE AND EQUIPMENT WITH 3/4" O GC TO VERIFY THERE IS A FLOOR OR LANDING AT THE SAME
<br /> MACMINE ON LEVEL PORTION OF SIDEWALK/ACCESSIBLE ROUTE PLYWOOD BACKING BOARD.EXISTING PANEL WITH NEW ELEVATION ON EACH SIDE OF DOOR.NOTIFY TENANT'S NORTH a
<br /> AND ON TOILET ROOM SIDE OF BUILDING WHERE POSSIBLE.HOSE ENERGY MANAGEMENT SYSTEM.REFER TO ELECTRICAL ARCHITECT IF VARIES.
<br /> BIB TO BE ON SAME SIDE AS WATER VENDING MACHINE. DRAWINGS FOR MORE DETAIL. O SEE 2/A1.4 FOR ENTRY WALK-OFF CARPET DETAIL. Sheet
<br /> NOTE:
<br /> ALL PLUMBING PIPING TO BE INSULATED IN EXTERIOR WALL. COORDINATE WHICH STATES REQUIRE VENDING MACHINE WITHO EXISTING 4"MIN,CONCRETE PAD.
<br /> FDS. 1� COMMUNICATION BOARD:PROVIDE SIM. FIRE RETARDANT.
<br /> NOTE,
<br /> O EXISTING(2)TOILET EXHAUST OPENINGS 6"DIA.WITH METAL O EXISTING PRE-ENGINEERED METAL BUILDM6(PEMB) UL CLASS PLYWD. BOARD-3/4"X 4'W X 8'H MOUNTED 24" ,0
<br /> DUCT THRU WALL LOCATED OVER TOILET AREA AND CAPPED
<br /> NO PLUMBING OR CONDUIT TO PASS ENDER THE SALES FLOOR.EXPECT IN TOILET I OFFICE I VEST 8 STRUCTURE WITH 518"GWB 6"ABOVE CEILING GRID A.F.F.SECURE TO FRAMING SO IT HOLDS 225LBS.SEE
<br /> SUPPORT AREA. FOR FUTURE TENANT CONNECTION.REFER TO MECHANICAL SECURED 70 GIRTS AT 2'-0"QO..C.FINISH PER FINISH SHEET A/1.0.FOR LOCATION.
<br /> DRAWINGS. SCHEDULE ON SHEET A1.4. 11 NEW GLAZING
<br /> NOTE: O3 EXISTING CONCRETE SIDEWALK;SEE SITE PLAN FOR LIMITS.MIN. O7 EXISTING AL./GL.STOREFRONT.
<br /> 104"WIDTH.
<br /> REFER TO INTERIOR FINISH SCHEDULE FOR ADDITIONAL INFORMATION
<br />
|