Laserfiche WebLink
existing screen depths of MW-31) and MW-51) lo confirm the vertical extend of 1,2-DCA <br /> contamination. CPT#3,44,and#5 confirmed that 1,:',-DCA vertical contamination does not extend <br /> beyond 85', therefore a third depth of monitoring well will not be required for MW-7 and MW-8. <br /> The soil samples will be taken for analytical testing rom 20'to 85' on 5' intervals. Water samples i <br /> will betaken with well development. Analytical testing of soil and water will be for BTEX,TPHg, <br /> Stoddard Solvent, Fuel Oxygenates and Fuel Additives. In addition water samples will be tested <br /> for Halogenated Hydrocarbons. <br /> Prior to starting work an Underground Service Alert ticket, a EHD boring permit, and City of <br /> Stockton encroachment permit will be acquired. <br /> Please contact,this office at (916) 729-5184 if there are any questions. <br /> o -�Esslo'�i <br /> Respectfully submitted, Ppg� <br /> Foothill Engineering ��" <br /> u 7 <br /> * EXP 12-31-07 it <br /> �S'1 Cry1L ��P 0 <br /> Michael Vlach, P.E. ���fiC�►-�F� 1 <br /> Attachments: Site Map, and Wel Section <br /> cc: Mrs. Helen Higgins <br /> 3 <br />