Laserfiche WebLink
1. lµ <br /> 110 2nd Avenue South #D7 Pacheco,CA 94553 5560 <br /> Inc.McCampbell Analytical, 1 Telephone 925-798-1620 Fax 925-798-1622 <br /> Website www rrrccampbell cnm E-mail main@mecampbell com <br /> QC SUMMARY REPORT FOR SW8021B/8015Cm <br /> W O Sample Matrix Water QC Matrix Water WorkOrder 0503501 <br /> EPA Method SW802113I8015Cm Extraction SW5030B BatchlD 15630 Spiked Sample ID 0503501-014A <br /> Sample Spiked MS` MSD* MS-MSD` LCS. LCSD HR <br /> e Criteria(%) <br /> Analyte <br /> pg/L pg/L % Rec % Rec %RPD %Rec %RecLCS I LCSDTPH(btex)£ ND 60 999 967 327 102 94870-130MTBE ND 10 953 91 2 434 932 939 70- 130 <br /> Benzene ND 10 106 103 249 979 103 531 70-130 70-130 <br /> Toluene ND 10 104 100 348 101 101 0 70-130 70- 130 <br /> Ethylbenzene ND 10 105 104 1 18 101 102 0 845 70- 130 70-130 <br /> Xylenes ND 30 913 91 0 366 91 903 0 735 70-130 70- 130 <br /> %SS 98 10 111 110 1 02 106 112 567 70- 130 70-130 <br /> All target compounds to the Method Blank of this extraction batch were ND less than the method RL with the following exceptions <br /> NONE <br /> BATCH 15630 SUMMARY <br /> Sample ID Date Sampled Date Extracted Date Analyzed Sample ID Date Sampled Date Extracted Date Analyzed <br /> 0503501-011A 3/28/05 3131/05 9 42 AM 3/31/05 9 42 AM 0503501-012A 3/28/05 3/31105 10 48 AM 3131/05 10 48 AM <br /> 0503501-013A 3/28/05 3/31/05 11 54 AM 3131105 11 54 AM 0503501-014A 3/28105 3/31105 1 00 PM 3/31/05 1 00 PM <br /> 0503501-015A 3/28/05 3131/05 1 33 PM 3131105 1 33 PM 0503501-016A 3/28/05 3131105 2 06 PM 3/31/05 2 06 PM <br /> 0503501-017A 3/28/05 3/31/05 2 39 PM 3/31/05 2 39 PM 0503501-01 8A 3/28/05 3/31/05 3 12 PM 3/31105 3 12 PM <br /> 0503501-019A 3/28105 3131/05 5 08 PM 3/31/05 5 08 PM 0503501-020A 3/28105 3/31/05 1 23 PM 3/31105 1 23 PM <br /> 0503501-021A 3/28105 3131/05 1 56 PM 3/31/05 1 56 PM 0503501-022A 3128105 3/31/05 2 29 PM 3/31/05 2 29 PM <br /> 0503501-023A 3128105 3/31105 3 03 PM 3/31/05 3 03 PM 0503501-024A 3/28/05 3/31/05 4 10 PM 3/31/05 4 10 PM <br /> 0503501-025A 3/28/05 3/31105 3 05 PM 3/31/05 3 05 PM 0503501-026A 3128/05 3/31/05 3 35 PM 3/31/05 3 35 PM <br /> 0503501-027A 3128/05 4101/05 5 28 AM 4101/05 5 28 AM 0503501-028A 3128/05 4101105 5 58 AM 4101105 5 58 AM <br /> 0503501-029A 3/28/05 4/01105 6 27 AM 4/01105 6 27 AM 0503501-030A 3/28105 4101/05 6 57 AM 4/01/05 6 57 AM <br /> 0503501-030A 3/28/05 4102/05 4 38 AM 4102/05 4 38 AM <br /> MS=Matrix Spike MSD=Matrix Spike Duplicate LCS=Laboratory Control Sample LCSD=Laboratory Control Sample Duplicate RPD=Relative Percent Deviation <br /> %Recovery=100*(MS-Sample)I(Amount Spiked) RPD=100*(MS- MSD)I((MS+MSD)/2) <br /> "MS/MSD spike recoveries and I or°/RPD may fall outside of laboratory acceptance criteria due to one or more of the following reasons a)the sample is inhomogenous <br /> AND contains significant concentrations of analyte relative to the amount spiked or b)the spiked sample is matrix interferes with the spike recovery <br /> £TPH(btex)=sum of BTEX areas from the FID <br /> #cluttered chromatogram sample peak coelutes with surrogate peak <br /> IO !A=not applicable or not enough sample to perform matnx spike and matrix spike duplicate <br /> NR=analyte concentration in sample exceeds spike amount for soil matrix or exceeds 2x spike amount for water matnx or sample diluted due o high matrix or analyte content <br /> DHS Certification No 1644 QA/QC Officer <br />