Laserfiche WebLink
r _ <br /> , <br /> I ` r <br /> 31 January 2003 <br /> AGE-NC Project No 96-0232 <br />' Page 17 of 17 N <br /> _ II <br /> (OS-1),performance of a ground water aquifer pumping test and performance of an ozone sparging <br />' test Wells MW-14 through MW-18 and OS-1 were installed in October 2002 under SJCE14D <br /> permit Aground water aquifer pumping test was performed at the Rocky's Restaurant in December <br /> 2002 utilizing wells MW-14 (screened 40 to 60 feet bsg) and MW-15 (screened 65 to 75 feet bsg) <br />' to extract ground water AGE is currently in the process of setting up and coordinating with the <br /> Rocky's Restaurant owners for a 30 day ozone spare test,we anticipate starting the ozone sparge test ; <br />' in February 2003 Upon completion of the ozone sparge test, AGE will submit a report of findings <br /> to the RWQCB detailing the results of the above well installations, the ground water aquifer <br /> pumping tests and the ozone sparge test y <br /> 8.0. LIMITATIONS <br />' Our professional services were performed using that degree of care and skill ordinarily exercised by <br /> environmental consultants practicing in this or similar localities The findings were based mainly <br />' upon analytical results provided by an independent laboratory Evaluations of the hydrogeologic <br /> conditions at the site for the purpose of this investigation are made from a limited number of <br /> available data points (ground water samples), and subsurface conditions may vary away from these <br /> data points No other warranty,expressed or implied, is made as to the professional interpretations, <br /> opinions and recommendations contained in this report <br /> 1 I <br /> 1 <br /> 1 I II <br /> J <br /> 4 <br /> l <br /> 1 <br /> f 1 <br /> 4 <br /> 1 t �, Advanced GeoEnvironmental,Inc <br /> ti I <br /> i <br /> I <br />