31 August 2005 <br /> AGE-NC Project No 96-0232 <br /> Page 8 of 30 <br /> P24,P25,P28,P30,P31,P32,P34 and P35 samples at concentrations as high as 11,000µg/l <br /> Analytical results of grab ground water samples are summarized in Table 3 The area of the <br /> most intense MTBE-impact to ground water was encountered in the southwestern dispenser <br /> area,extending northward to the mini-mart and southwestward to the southwest corner of the <br /> subject property <br /> A report of findings (Quarterly Report - Second Quarter 2000, dated 19 July 2000) <br /> documenting investigation activities performed in April 2000 was prepared by AGE and <br /> submitted to the SJCEHD and the RWQCB <br /> • May 2000 - Six multi-level ground water monitoring wells (MW-8 through MW-13) were <br /> installed on and off-site to maximum depths of 150 feet bsg (Figures 2 and 3) Well <br /> construction details and boring logs for MW-8 through MW-13 are in Appendix F <br /> Twenty-three initial ground water samples were collected from wells MW-8 through <br /> MW-13 Laboratory analysis of initial ground water samples detected MTBE in seven <br /> samples at concentrations as high as 2,500 µg11 (MW-13A), TPH-g in five samples at <br /> concentrations as high as 130 µg/l, TPH-d in fourteen samples at concentrations as high as <br /> �} 940µg11, BTEX compounds in two samples at concentrations as high as 33 µg11, TAME in <br /> one sample at a concentration of 87 µg/l,ETBE in one sample at a concentration of 2 5 µg/l, <br /> TBA in four samples at concentrations as high as 24 µg11 and ethanol in 21 samples at <br /> concentrations as high as 1,200,000µg/l Analytical results of monitoring well water samples <br /> are summarized in Table 7 <br /> Due to the high concentrations of ethanol, which were detected only in samples collected <br /> from the multi-level monitoring wells, samples of the '/4-inch coated bentonite pellets <br /> (Sinclair Services) were submitted in a VOA container filled with bottled water for <br /> laboratory analysis for ethanol The laboratory analysis detected dissolved ethanol at a <br /> concentration of 22,000 µg11 (Appendix D) Thereafter,AGE requested MSDS sheets from <br /> Sinclair Services, as well as other industry bentonite pellet manufacturers from Colloid <br /> Environmental Technologies Co (CETCO) and Polymer Drilling Systems (Pel-Plug) The <br /> MSDS sheets from all three bentonite pellet manufacturers listed ethyl alcohol and ethyl <br /> acetate on the bentonite coating The high ethanol concentrations detected in samples from <br /> the multilevel wells appeared to be due to introduction of the bentonite pellets <br /> Interim remedial action was continued at the site by continuously pumping ground water <br /> from EW-1 at a rate of 2 gallons per minute and discharged into a 5,900-gallon poly tank <br /> Three grab ground water samples were collected during May 2000 from the EW-1 discharge, <br /> MTBE was detected at concentrations of 650 µg/l, 800 µg11 and 490 µg/l Analytical results <br /> of EW-1 grab samples are summarized in Table 7 <br /> Advanced GeoEnvironmental,Inc <br />