FOOD SERVICE EQUIPMENT Section 11400 <br /> 8. Strip Curtains: each walk-in door shall have polyester reinforced clear vinyl strip <br /> curtains. <br /> 9. Entrance Doors: Each door shall have a 'J8'thick sheet aluminum diamond plate <br /> kick panel 3'-0" high on the exterior and interior door panels and adjacent door <br /> jambs. <br /> 10. The wall panels exposed to the kitchen shall have a 16 gauge stainless steel rub <br /> rail. <br /> J. This assembly shall be installed by factory personal and or factory approved installers <br /> with written certification provided by the manufacturer to the Architect and Consultant. <br /> K. Walk-in assembly shall be installed into an insulated concrete pit as shown on the <br /> drawings. Allowances are to be made for floor finishes. All floor finishes are to be the <br /> same as in the kitchen. Kitchen Equipment Contractor is to verify finishes and <br /> thickness and allow for proper clearance at walk-in door. <br /> L. The walk-in manufacturer shall provide complete structural design, prepared by a <br /> registered professional engineer licensed in the State of California. Submit to the <br /> Architect for review prior to submittal to D.S.A. as a differed approval item. Design <br /> shall be in accordance with the requirements of CCR, Title 24, Chapter 17 including all <br /> requirements for the Seismic Zone and suspended equipment. Include the following <br /> items as a minimum in the rational analysis: <br /> 1. Critical load compensation. <br /> 2. Load Factors if any. <br /> 3. Stress increases if any. <br /> 4. Critical distribution of loads. <br /> 5. Anchorages. <br /> 6. Stability against over turning lateral force analysis, torsional movements, including <br /> those at connections. <br /> 7. Distribution of horizontal shear. <br /> M. Remote Refrigeration: The refrigeration package shall be pre-engineered and <br /> factory assembled unit, trade name"MULTI-RAK", as manufactured by KAIRAK, 23955 <br /> President Avenue, Harbor City, CA 90710 Phone: (310) 530-1766 Fax: (310) 530-3306 <br /> e-mail: Engineedng@Kairak.com . Assemblies shall meet California Code of <br /> Regulations Title 20 Sections 11601 through 1608 dated July 2006 Appliance Efficiency <br /> Regulations. <br /> Contractor shall furnish and install, where shown on plans, ( ) KAIRAK <br /> U.L. approved "MULTI-RAK"Air-cooled Remote Refrigeration Package, Model <br /> MAE 2-2EO, With Control Panel, 208-230 Volts, 3 Phase, 60 Hz. Refrigeration system <br /> shall be housed in a weather protected enclosure. The frame, enclosure, and <br /> panels shall be fabricated of galvanized steel. Entire frame shall be <br /> pre-assembled, welded, cleaned, and painted with a prime coat of zinc <br /> chromate then finished with a coat of baked enamel epoxy based paint. The <br /> condenser shall be sectional, removable multi-circuited with rifled tube <br /> slotted finned and shall be designed for 20°FTD. Condenser fan motors shall <br /> be mounted on the top of the enclosure. <br /> 1. REFRIGERATION UNITS <br /> Valentine M. Peyton Elementary School 10 Job No. 2749 <br />