My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0012559
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
121
>
3500 - Local Oversight Program
>
PR0544166
>
ARCHIVED REPORTS XR0012559
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2019 6:01:25 PM
Creation date
2/22/2019 1:52:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012559
RECORD_ID
PR0544166
PE
3528
FACILITY_ID
FA0005252
FACILITY_NAME
GREYHOUND LINES INC
STREET_NUMBER
121
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13730011
CURRENT_STATUS
02
SITE_LOCATION
121 S CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
385
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y17..�" Q�•a <�r Y�.fa:fi" ram -�:'� .�, �.e:;,w� '�` •�� .r u.. <br /> �• - ES BNGINEERING•SCIENCE - <br /> • r�2P�IQL: y <br /> AIR ::CML"4.*_SG c.:�ULPy�iT <br /> 7%=BRAT-C:I n:la MAIU7MIANCE <br /> ?=QOI]L--MI <br /> All monitoring izsrsUmencs must =e calibrated 4nd nainrained <br /> ?arzodicaill.y. The Limitations and =assible, tiources of errors for each <br /> tnstrumont must be understood by the operator. It is important t:>at the <br /> overator ensurnm that the instrument responds properly to the substances <br /> it 'dau designed tm monztor. Below are the caltbrar.Lon and mainteaance <br /> procedures _or the �itatavae=eCP [I 7hotoLonizaraan letectmr and <br /> 31asensar,t_ camoustible gas _ndieator. <br /> PHOTOVAC-IiIP IT <br /> The photcxontzation detector must be calibrated each day prior to <br /> use in the field. A claibration gas (100 ppm tsobutylene) will be taken <br /> tato the field to perform routine calioration. calibration procedures <br /> for the Photaven-TIP are as follows: <br /> 1. Turn the instrument on." IE ^the 'law bat" indicator appears. <br /> the battery must be charged prior co using (time to full <br /> recharge is approszmately 16 hours). Allow tie Lnsrsument <br /> several minutes far the pump to come on and Ear the ion cell to <br /> I coma into equi,Li.brxum. <br /> Z. Zero the instrument: Loosen the black locking rings (turn thea <br /> clockwisel an both the "ZERA" and "SP1-,N" knobs. Set the "Sp1m' <br /> knob to "5" and lack (turn the Lacking ring counterclockwise). <br /> )text set+ the liquid crystal display to sero by tur3sing the <br /> "ZERO" knal , Lack the "ZERO" knob into place by ruining the <br /> Locking ring cauntP-relOCkVL-qe. <br /> 3. Calibrate case instrument: ?ill the plastic bladder with <br /> calibraton gas (not too full.) and attach tt to tate phatovae <br /> via a teflon tsizing and Locking nut. Allow a moment for <br />
The URL can be used to link to this page
Your browser does not support the video tag.