Laserfiche WebLink
KLEIN FELDER <br /> TABLE 1 <br /> MARLEY COOLING TOWER <br /> STOCKTON, CALIFORNIA <br /> Lysimeter Sampling <br /> (September 27, 1988) <br /> Station Residual Time Vacuum Sample ID Notes <br /> Vacuum Reset <br /> centibars centibars <br /> L-5A 10 8:55 50 ----- No recovery. <br /> L-513 0 9:15 50 ----- No recovery. <br /> L-5C 0 9:25 50 ----- No recovery. <br /> Replaced clamps on <br /> discharge line. <br /> L-246 3 9:55 50 16256 250 nil greenish <br /> yellow liquid. <br /> L-247 4 10:05 50 16257 250 nil greenish <br /> yellow liquid. <br /> L-248 20 10:15 50 16258 175 ml of orangish <br /> liquid. <br /> L-242 24 10:35 50 16259 200 ml of orangish <br /> liquid. <br /> L-243 16 10:45 50 16260 250 ml of orangish <br /> liquid. <br /> L-244 25 10:52 50 18261 150 ml of greenish <br /> yellow. <br /> L-232 12 11:14 50 ----- No recovery. <br /> L-233 16 11:21 50 ----- No recovery. <br /> L-234 6 11:30 50 ----- No recovery. <br /> L-239 16 11:58 50 16262 75 nil clear liquid. <br /> L-240 19 12:05 50 16263 125 ml clear liquid. <br /> L-241 22 12:10 50 16264 150 nil clear liquid. <br />