Laserfiche WebLink
LancasterAnalysis Report <br /> Laboratories <br /> 2425 New Holland Pike PO Box 12425 Lancaster PA 17605-2425.717 656-2300 Fax 717 656 2681 www lancasterlabs corn <br /> Page 1 of 2 <br /> Lancaster Laboratories Sample No WW 4547141 <br /> MW-15-W-050617 Grab Water <br /> Facility# 90557 Job# 386843 GRD <br /> 139 S Center-Stockton 70607700391 MW-15 Account Number 10906 <br /> Collected 06/17/2005 14 35 by AS <br /> Submitted 06/21/2005 08 50 ChevronTexaco <br /> Reported 06/29/2005 at 23 08 6001 Bollinger Canyon Rd L4310 <br /> Discard 07/30/2005 San Ramon CA 94583 <br /> 15139 <br /> As Received <br /> As Received Method Dilution <br /> CATUnits Factor <br /> No Analysis Name CAS Number Result Detection <br /> Limit 5 <br /> 01728 TPH-GRO - Waters <br /> n a 6,600 250 ug/1 <br /> The reported concentration of TPH-GRO does not include MTBE or other <br /> gasoline constituents eluting prior to the C6 (n-hexane) TPH-GRD range <br /> start time 4,000 280 ug/i 10 <br /> 05553 TPH - DRO CA LUFT (Waters) n a <br /> 01412 Methanol and Ethanol <br /> 01414 Methanol (by Direct In3ection) 67-56-1 N D <br /> 200 ug/1 1 <br /> 02500 TPH Fuels by GC (Waters) <br /> 1,100 400 ug/l 10 <br /> 02501 Total TPH n a 10 <br /> 02508 TPH Motor Oil C16-C36 <br /> n a 1 100 400 ug/1 <br /> TPH quantitation is based on peak area comparison of the sample pattern to <br /> that of a hydrocarbon component mix calibration in a range that includes <br /> C6 (n-octane) through C40 (n-tetracontane) normal hydrocarbons <br /> Due to the nature of the sample matrix the chlorobenzene surrogate standard <br /> recovery is above the range of specifications <br /> The observed sample pattern is not typical of motor oil The reported <br /> result is due to individual peaks eluting in the motor oil range <br /> 01594 BTEX+5 Oxygenates+EDC+EDB+ETOH <br /> 01587 Ethanol 64-17-5 N D <br /> 100 ug/l 2 <br /> 1 ug/l 2 <br /> 02010 Methyl Tertiary Butyl Ether 1634-04-4 N D 1 ug/l 2 <br /> 02011 di-Isopropyl ether 108-20-3 N D <br /> 3 N D 1 ug/l 2 <br /> 02013 Ethyl t-butyl ether 637-92- ug/ 2 <br /> 02014 t-Amyl methyl ether 994-05-8 N D 75-65-0 130 10 1 1 <br /> ug/ 2 <br /> 02015 t-Butyl alcohol 5 ug/l 10 <br /> 05401 Benzene 71-43-2 1 300 <br /> 107-06-2 N D 1 ug/1 2- <br /> 05402 <br /> 05402 1,2-Dichloroethane 1 ug/l 2 <br /> 05407 Toluene 108-88-3 4 ug/l 2 <br /> 05412 1,2-Dibromoethane 106-93-4 N D 15 ug/l 10 <br /> 05415 Ethylbenzene 100-41-4 470 ug/l 2 <br /> 06310 Xylene (Total) <br /> 1330-20-7 20 1 <br /> The reporting limits for the GC/MS volatile compounds were raised <br /> because sample dilution was necessary to bring target compounds into the <br /> calibration range of the system <br /> State of California Lab Certification No 2116 <br />