COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 1:59:08 PM
Creation date
2/26/2019 11:59:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Pale of <br /> 8. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums 0 <br /> Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br /> Test Method Developed By: 0 Sump Manufacturer 0 Industry Standard N Professional Engineer <br /> ❑Other(Speci)5) <br /> Test Method Used: ❑Pressure 0 Vacuum 2 Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: 00606 ' S- STS Equipment Resolution: -0.U Fes,i <br /> Fill Sump# 5y' Fill Sump#(j'ZMttSi Fill Sump#�37s Fill Sump# <br /> Sump Diameter. czod 'E�„ <br /> Sum Depth: Jc' Je-a„ <br /> Height from Tank Top to Top of 20 r <br /> Highest Piping Penetration: �( 9 <br /> Height from Tank Top to Lowest 3� n �l <br /> Electrical Penetration: ✓T 01 X34 <br /> Condition of sump prior to � <br /> testing: �' <br /> Portion of Sump Tested 36" L3 G <br /> Sump Material: p <br /> Wait time between applying <br /> pressure/vacuum/water and !p ,l t Xz> <br /> starting test: 04 !x-) <br /> Test Start Time: I 1 '. 50t ALA .SSA'k4 <br /> Initial Reading(Rj): 2 •1416 " 3•�8 . '' .!1'2-1 " Z •Sog3 " <br /> Test End Time: t2 : 15 P" lam' 3? P" NM Y 13 Alt•1 <br /> Final Reading(Rr•): 2•`ftQ-1 I I 7871 �1 1L 2,SU37" <br /> Test Duration: !iS' P1 t I's. f-41 Z� /S A-(1 /s H) <br /> Change in Reading(RF-Ri): b•GYj t 2 <br /> Pass/Fail Threshold or Criteria: i/- •�C��" _o. C,oa +-_p <br /> Test Result: Pass ❑Fail )n Pass ❑Fail VPPass ❑ Fail Pass ❑Fail <br /> Is there a sensor in the sump? >4 Yes ❑No %Yes 0 No Yes ❑No WYes ❑No <br /> Does the sensor alarm when <br /> either product or water is 14A Yes ❑No 0 NA J.Yes ❑No ❑NA fPes ❑No ❑NA Yes 0 No ❑NA <br /> detected? <br /> Was sensor removed for testing? Yes ❑No ❑NA es ❑No ❑NA tkes ❑No ❑NA Yes 0 No ❑NA <br /> Was sensor properly replaced and )Q Yes 0 No ❑NA yLYes 0 No ❑NA ?I Yes 0 No ❑NA Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.