Laserfiche WebLink
Apr 28 14 03:56a Reliable Petroleum 2098458953 p.3 <br /> 04/28/2014 7 OEAM FAX 19252 371 Guadalupe Sanchez X0003/0015 <br /> Monitoring System Certification <br /> D. Results of Testing/Serviciug <br /> Software Version Installed: 329.01 <br /> Corn iete the foil ing checklist: _ <br /> ® Yes '] No* Is the audible a:arm operational? <br /> ® Yes [I No* is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected, functionally toted,and confirmed operational? <br /> ® Yes ❑ No" Were all sensors installed at lowest point of secondary i=tainrncrt and positioned so that other egWpment N?611 <br /> not into-Ttare with their proper operation? <br /> ❑ Yes p No* If alarms are relayed to a rcmote monitoring station, is all communications equipment (e.g., modem) <br /> ® N/A Operational? <br /> ® Yes ❑ No* For pressurized piping systems; does the turbine automatically shut down if the piping secondary containment I <br /> ❑ N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) ®Swop/trench Sensors; ®Dispenser Contairunent Sensors. <br /> Did you canferrn Positive shut-down due to leaks and Sensor failure/discon,1e-ctioa? ®Yes; ❑No, <br /> (K Yes 0 Noy' For tank systems that utilize the monitoring system as the primary think overfill warning device (i.e., no <br /> E] NT/A mechanical overfill prevention vnlve is inset Aed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? if so,at what percent of tank capacity does the alarm trigger? 90'o <br /> ® Yes* Q No Was any monitoring equipment replaced? Ifyes,identify specific sensors,probes,or other entdpment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> 17 Yes* E No Was liquid found inside any secondary containment systems designed as d.*y systems? (Check all that apply) <br /> ❑Product; ❑ Water. Ifyes,describe causes m Section E,below. <br /> 19 Yes ❑ No* Was monitoring system set-up reviewed to ensure proper se;tutgs?Attach set up reports,if applicable <br /> Yes ❑ No* Is all monitoring equipment operational per manufamner's speci:ications? <br /> *In Sectlott E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Replaced annular sensor in the 87 Siphon tank. Inspector on site. <br /> APR <br /> EIVVIRO E.�-,�. HEAL H <br /> DEPA13IA4EA,, <br /> Page 2 of 4 <br />