My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:26:33 PM
Creation date
2/26/2019 12:19:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UL/ULG Listed Red ThreadiN IIA Piping System <br />RED THREAD IIA PIPING <br />RED THREAD IIA Primary Piping <br />Nom. Pipe Size <br />Part Number <br />Pipe Length <br />(ft.) <br />(In.) <br />mm <br />2 <br />50 <br />011020-069-1 <br />15 <br />2 <br />50 <br />011020-069-2 <br />22-25 <br />2 <br />50 <br />011020-069-3 <br />26-30 <br />3 <br />80 <br />011030-069-1 <br />15 <br />3 <br />80 <br />011030-069-2 <br />22-25 <br />3 <br />80 <br />011030-069-3 <br />26-30 <br />4 <br />100 <br />011040-071-1 <br />15 <br />4 <br />100 <br />011040-069-2 <br />22-25 <br />4 <br />100 <br />011040-071-3 <br />26-30 <br />DIMENSIONAL DATA <br />RED THREAD IIA <br />Secondary Containment Piping <br />Nom. Pipe <br />Size <br />Part Number <br />Pipe Length <br />(ft.) <br />(In.) <br />mm <br />3 <br />80 <br />011030-069-4 <br />15 <br />3 <br />80 <br />011030-069-5 <br />22-25 <br />3 <br />80 <br />011030-069-6 <br />26-30 <br />4 <br />100 <br />011040-077-5 <br />15 <br />4 <br />100 <br />011040-069-5 <br />22-25 <br />4 <br />100 <br />011040-077-6 <br />26-30 <br />6 <br />150 <br />011060-120-5 <br />15 <br />6 <br />150 <br />011060-1204 <br />22-25 <br />6 <br />150 <br />011060-120-6 <br />26-30 <br />Nominal <br />Pi <br />Pipe <br />Size (InJ <br />mm) <br />Nominal <br />I.D. <br />(InJlnm) <br />Nominal <br />O.D. <br />(InJrnrn) <br />Nominal <br />Wall <br />Thickness <br />(InJITIm) <br />Nominal <br />Weight <br />(IbsJftJkg-m) <br />Pressure/ <br />Temperature <br />Max. Rating <br />Mill Test <br />Pressure <br />(psig/MPa) <br />External Pressure <br />Max. Rating <br />(psig/MPa) <br />750F/24°C 1500F/660C <br />2 <br />2.235 <br />2.375 <br />.070 <br />0.5 <br />250 psig @ 150°F <br />375 <br />85 80 <br />50 <br />57 <br />61 <br />1 78 <br />0 74 <br />1.72 MPa @ 66°C <br />2 59 <br />57 .55 <br />3 <br />3.360 <br />3.500 <br />.070 <br />0.7 <br />175 psig @ 150°F <br />300 <br />36 34 <br />80 <br />85 <br />90 <br />2."= <br />1.04 <br />1.21 MPa @ 66-C <br />2.07 <br />.25 .23 <br />4 <br />4.360 <br />4.560 <br />.085 <br />1.2 <br />125 psig @ 150'F <br />265 <br />34 30 <br />100 <br />'1- <br />116 <br />2.16 <br />1.79 <br />0.86 MPa @ 66'C <br />1.83 <br />.23 .21 <br />6 <br />6.408 <br />6.678 <br />.135 <br />2.4 <br />20 psig @ 150°F <br />265 <br />22 20 <br />150 <br />1 163 <br />1 170 <br />3Z 3 <br />1 3.51 <br />0,14 a 66-C <br />1 83 <br />.15 .14 <br />Bending Radius, Minimum <br />Nominal <br />RED THREAD IIA Pipe <br />PROPERTY <br />psi @ 75°F <br />MPa rc 24°G <br />psi @ 150°F <br />COPT766-C <br />66-C <br />110 140 204 <br />Axial Tensile (ASTM D2105) <br />r33.5 42.7 612 <br />Ultimate Stress <br />10,300 <br />71.0 <br />8,200 <br />565 <br />Design Stress <br />2,575 <br />17.5 <br />2,050 <br />14.1 <br />Modulus of Elasticity <br />1.82 x 106 <br />12548 <br />1.42 x 106 <br />9791 <br />Axial Compression (ASTM D695) <br />Ultimate Stress <br />33,300 <br />230.0 <br />25,600 <br />177.0 <br />Design Stress <br />8,300 <br />57.2 <br />6,400 <br />441 <br />Modulus of Elasticity <br />1.26 x 106 <br />8687 <br />.89 x 106 <br />6136 <br />Beam Bending (SFPTM) <br />Ultimate Stress <br />23,000 <br />159.0 <br />19,200 <br />132.0 <br />Design Stress(4) <br />2,900 <br />20.0 <br />2,400 <br />165 <br />Modulus of Elasticity <br />2.18 x 106 <br />15031 <br />1.70 x 106 <br />1171 <br />(Long Term per ASTM D2925) <br />Hydrostatic Burst (ASTM D1599) <br />Ultimate Hoop <br />Tensile Stress <br />34,000 <br />234 <br />39,200 <br />271 <br />Hydrostatic Design (ASTM D2992) <br />2"-3" <br />2'& 3" <br />2" & 3" <br />2 & 3' <br />Procedure A <br />9,410(5) <br />64.9151 <br />7,400(7)1 <br />Cyclic 150 x 106 <br />4"-6" <br />4"-6" <br />4"-6" <br />e, <br />Cycles <br />13,040(6) <br />89.9(6: <br />10,450 <br />- <br />Coefficient of Linear <br />0.88 x 10-5 in./in./'F <br />Thermal Expansion (SFPTM) <br />1.58 x 10' mm;rrmr''C <br />Specific Gravity <br />1.8 <br />Flow Factor <br />W -in Will;n- r'noffirio f <br />Bending Radius, Minimum <br />Nominal <br />Pipe Size 2" <br />3" 4" 6" <br />(Inches) <br />Ft. 75 <br />110 140 204 <br />M 21.3 <br />r33.5 42.7 612 <br />(1) All values except pressure -temperature <br />maximum rating are nominal values. Tolerances <br />or maximum/minimum limits can be obtained <br />from Smith Fibercast. <br />(2) All sizes can accept full vacuum pressures <br />at maximum temperature ratings. <br />(3) Ultimate and allowable design stresses are <br />based on minimum reinforced wall thickness. <br />Pipe is manufactured in compliance with ASTM <br />D2996. <br />(4) Design bending stress is 118 of ultimate to <br />account for combined stress (i.e. bending and <br />pressure). <br />(5) Design stress is based on long term cyclic <br />fatigue data using ASTM D2992 test method. <br />However, all testing is not complete at time of <br />printing. <br />(6) For RED THREAD IIA pipe the hydrostatic <br />cyclic design stress was determined at 150° and <br />200°F, per ASTM D2992 Procedure A. Based <br />on this data, the extrapolated value at 75`F is <br />13,030 psi. <br />(7) For RED THREAD IIA pipe the hydrostatic <br />cyclic design stress was determined at 75° and <br />200°F, per ASTM D2992 Procedure A. Based <br />on this data, the extrapolated value at 150`F is <br />7 cnn nsi <br />
The URL can be used to link to this page
Your browser does not support the video tag.