My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:26:33 PM
Creation date
2/26/2019 12:19:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Mechanical Properties <br />Pipe Property <br />Value <br />7SoF <br />24°C <br />Thermal <br />200°F <br />93°C <br />Method <br />psi <br />MPa <br />psi <br />MPa <br />Axial Tensile <br />10.7 x 10-1 in/in °F <br />19.3 x 10-1 mm/mm °C <br />ASTM D696 <br />Expansion <br />171 129 <br />Ultimate Stress <br />9,530 <br />65.7 <br />100 <br />16,585 <br />45.4 <br />ASTM D2105 <br />Modulus of Elasticity <br />1.68 x 106 <br />111,584 <br />Specific Gravity <br />11.42 x 106 <br />19,791 <br />ASTM D2105 <br />Poisson's Ratio, v (v jf11 <br />1 <br />0.35 (0.61) <br />Axial Compression <br />Ultimate Stress <br />112,510 <br />186.3 <br />18,560 <br />159.0 <br />1 ASTM D695 <br />Modulus of Elasticity <br />0.677 x 106 <br />14,668 <br />10.379 x 106 <br />12,613 <br />1 ASTM D695 <br />Beam Bending <br />Modulus of Elasticity (Long Term) 12.6 x 106 <br />117,927 <br />10.718 x 106 <br />14,951 <br />1 ASTM D2925 <br />Hydrostatic Burst <br />Ultimate Hoop Tensile Stress <br />140,150 <br />1277 <br />136,480 <br />1252 <br />1 ASTM D1599 <br />Hydrostatic Hoop Design Stress <br />Static 20 Year Life <br />LTHS - 95% LCL I - <br />18,203 - 14,689 <br />1125.5 - 101.3 <br />1 ASTM D2992 - Procedure B <br />Static 50 Year Life <br />LTHS - 95% LCL I - <br />16,788 -13,142 <br />1115.7 - 90.6 <br />1 ASTM D2992 - Procedure B <br />Parallel Plate <br />Hoop Modulus of Elasticity <br />3.02 x 106 120,822 <br />1 - <br />ASTM D2412 <br />Shear Modulus <br />1.76 x 106 112,135 <br />11.63 x 106 <br />111,250 <br />1 - <br />Typical Physical Properties <br />Pipe Property <br />Value <br />Value <br />Method <br />Thermal <br />in <br />mm <br />75°F 150°F <br />Conductivity <br />0.23 BTU/hr-ft-*F <br />0.4 W/m°C <br />ASTM D177 <br />Thermal <br />10.7 x 10-1 in/in °F <br />19.3 x 10-1 mm/mm °C <br />ASTM D696 <br />Expansion <br />171 129 <br />1.18 <br />0.89 <br />Absolute <br />100 <br />69 51 <br />0.48 <br />Roughness <br />0.00021 in <br />0.00053 mm <br />69 51 10.48 <br />Specific Gravity <br />1.8 <br />ASTM D792 <br />" ) Vha=The ratio of axial strain to hoop strain resulting from stress in the hoop direction. <br />'ah The ratio of hoop strain toaxlaIstrain resuIt! ngfrom stress inthe axlaIdirection. <br />"'The differential pressure between internal and external pressure which causes collapse. <br />M A 0.67 design factor Is recommended for short duration vacuum service. A full vacuum is equal <br />to 14.7 psig (0.101 MPa) differential pressure at sea level. <br />MA 0.33 design factor is recommended for sustained (tong -term) differential collapse pressure <br />design and operation. <br />National Oilwell Varco has produced this brochure forgeneral <br />information only, and it is not intended fordesign purposes. <br />Although every effort has been made to maintain the accuracy and <br />reliability of its contents, National Oilwell Varco in no way assumes <br />responsibility for liability forany loss, damage or injury resulting <br />from the use of information and data herein nor is anywarranty <br />expressed or implied. Always cross-reference the bulletin date <br />with the most currentversion listed at the web site noted in this <br />literature. <br />® 2017 National Oilwell Varco All rights reserved <br />FH1200ENG February 2017 <br />Ultimate Collapse Pressure <br />Size <br />Standard <br />Collapse Pressure (2)131(41 <br />psig <br />MPa <br />mm ft <br />in <br />mm <br />75°F 150°F <br />24°C <br />66°C <br />2 <br />50 <br />177 133 <br />1.22 <br />0.92 <br />3 <br />80 <br />171 129 <br />1.18 <br />0.89 <br />4 <br />100 <br />69 51 <br />0.48 <br />0.35 <br />6 <br />150 <br />69 51 10.48 <br />0.35 <br />Pipe Length <br />Size <br />Standard <br />Random <br />in <br />mm ft <br />m <br />ft <br />m <br />16.7-7.62 <br />2-6 <br />50-150 15 <br />4.57 <br />22-25 <br />RECEI ED <br />�EB 2 S 2018 <br />Fiber Glass SystemsENVIRON AL HEALTH <br />17115 San Pedro Avenue, Ste 200 <br />San Antonio, Texas 78232 USA T T <br />0 <br />Phone: 210 477 7500 <br />Fax: 210 477 7560 LISTED <br />Fiber Glass Systems I KOO/ Completion& Production Solutions fgspipe@nov.com nov.com/fgs <br />
The URL can be used to link to this page
Your browser does not support the video tag.