My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:26:33 PM
Creation date
2/26/2019 12:19:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cyr IVSD <br /> Appendix VI <br /> MONITORING SYSTEM CERTIFICATION JUL 2 4 2018 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of ENVIR014WiENTAL <br /> Regulations HEALTH I,)FQARTMENT <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> nm,., ARP MINI MART Bldg.No.: <br /> Site <br /> AddrPsc. Y� P�25775 PATTERSON PASS RD cit TRACY Zip: 95377 <br /> Facility Contact <br /> Persnn- <br /> RONAK Contact Phone No.: (510)677-4467 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 7/2/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check thea ro riate boxes to indicatespecific equipment ins ectedlserviced: <br /> Tank ID: 87 Tank Size: Tank ID: 87 SL Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG-I ® In-Tank Gauging Probe, Model: MAG-I <br /> ® Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor. Model: 409 <br /> ® Piping Sump/Trench Sensor(s), Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ® Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: PLLD ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: 90% ® Tank Overfill/High-Level Sensor. Model: 90% <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: 91 Tank Size: Tank ID: DIESEL Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG-I ® In-Tank Gauging Probe. Model: MAG-I <br /> ® Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor. Model: 409 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ® Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: PLLD ❑ Electronic Line Leak Detector. Model: <br /> ® Tank Overfill/High-Level Sensor. Model: 90% ® Tank Overfill/High-Level Sensor. Model: 90% <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> DispenserlD: I-2 DispenserlD: 3-4 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: 5-6 DispenserlD: 7-8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> DispenserlD: DispenserlD: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ED STEARNS Signature: <br /> Certification No.: A31048 License No: -7"t <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2n°STREET GALT,CA 95632 Date of Testing/Servicing: 7/2/18 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />