Laserfiche WebLink
Time In: <br />Time Out: <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sjgov.org/ehd <br />��Fda <br />Underground Storage Tank Program Service Request Inspection Report <br />Name of Facility: ARP MINI MART CORP <br />Date: 06/21/2018 <br />Address: 25775 S PATTERSON PASS RD, TRACY 95376 <br />Requestor: <br />Telephone: (925) 698-7022 <br />Program Element: 2308 - UST RETROFIT <br />Request #: SR0078577 <br />Inspection Type: 298 - UST RETROFIT REPAIR INSPECTION <br />Onsite Service Technician: Herbert "Andy" Pease <br />ICC Service Tech/Installer Exp. Date: 11/29/2018 <br />Manufacturer training: <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />Witnessed secondary piping testing of the new diesel product pipe from the newly installed UDCs to the diesel STP sump and <br />the existing 87 and 91 piping near the newly installed UDCs (3/4, 7/8) - 5 psi for 60 minutes. Witnessed soap testing of all <br />joints and fittings. All passed. <br />Verified 1/8 inch slope of the diesel piping from the UDCs to the diesel sump. The slope was not angled to the sump in all <br />areas and the installer adjusted the slope in several places. Passed. <br />Two piping crossovers were observed over the diesel piping with less than 2.5 inches. <br />-The vapor recovery line at UDC 7/8 was observed crossing over the diesel product pipe and touching the product pipe. A <br />small discoloration was observed where the two pipes met, seen when the vapor pipe was lifted slightly by the installer. <br />-Three PVC pipes were observed running over the top of the diesel product line approximately halfway between UDC 7/8 and <br />UDC 3/4. <br />According the the NOV piping installation instructions, "The 2.5" (64mm) critical dimension must be inspected in the field." <br />Piping crossovers must be verified as installed in accordance with the manufacturer's written instructions by the EHD prior to <br />backfill. <br />*The facility is not approved to operate. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: ronak patel, manager <br />EH Specialist: STACY RIVERA <br />EHD 23-01 Rev. 06/30/15 <br />Phone: (209) 468-3440 <br />FA0003619 SR0078577 SC298 06/21/2018 <br />Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />