ARCHIVED REPORTS - OZONE PILOT TEST & SEMI-ANNUAL GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
1201
>
2900 - Site Mitigation Program
>
PR0542081
>
ARCHIVED REPORTS - OZONE PILOT TEST & SEMI-ANNUAL GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/27/2019 9:53:41 AM
Creation date
2/27/2019 9:21:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
- OZONE PILOT TEST & SEMI-ANNUAL GROUNDWATER MONITORING REPORT - THIRD QUARTER 2014
RECORD_ID
PR0542081
PE
2960
FACILITY_ID
FA0024165
FACILITY_NAME
FERNANDO'S PLACE
STREET_NUMBER
1201
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14716003
CURRENT_STATUS
01
SITE_LOCATION
1201 S CENTER ST
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
264
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 20 March 2015 <br /> AGE Project No. 00-0769 <br /> ' Page 5 of 19 <br /> • Bromide was detected at concentrations ranging between 2.08 mg/1 (MW-3A) <br /> and 8.60 mg/I (MW-8A). <br /> • Bromate was detected at concentrations ranging between 1.28 mg/1 (MW-3A) <br /> and 6.16 mg/I (MW-1); Bromate concentrations were significantly above the State <br /> of California Primary MCL of 0.01 mg/I for drinking water. Additionally, the <br /> laboratory detection limit for bromate (1.0 mg/1) was above the Primary MCL of <br /> 0.01 mg/I (Table 5). However, bromate concentrations were significantly above <br /> the State of California Primary MCL in baseline samples collected in June 2013, <br /> ' prior to ozone injection. <br /> • Nitrite as N and Nitrogen were detected at concentrations ranging between 1.20 <br /> mg/I in MW-3A and 9.48 mg/I in MW-2A (Nitrite as N) and between 1.23 mg/I in <br /> ' MW-3A and 12.4 mg/I in MW-2A (Nitrogen as N). <br /> • Chemical Oxygen Demand (COD), pH, electrical conductivity, total dissolved <br /> ' solids (TDS), chlorine, sulfate, and total alkalinity were all detected at low to <br /> normal background concentrations (Table 5). <br /> • Ammonia, dissolved sulfide, orto-phosphate, and fluoride were not detected <br /> above laboratory reporting limits in the groundwater samples analyzed in June <br /> 2014 (Table 5). <br /> ' Analytical results of groundwater samples collected in June 2014 are summarized in <br /> Tables 2, 4, and 5. The laboratory reports (CTEL Lab Project. No. CT214-1406022), <br /> quality assurance/quality control reports, and chain-of-custody forms are included in <br /> Appendix E. Electronic deliverable format (EDF) files and depth to water data were <br /> uploaded to the State GeoTracker database system. Graphs illustrating depth to <br /> ' groundwater, groundwater elevation and TPH-g concentrations versus time (trend <br /> graphs) for each hydrogeologic unit are presented in Appendix F. <br /> JUL Y 2014.- <br /> On <br /> 014:On 01 July 2014, a progress-pilot test monthly monitoring event was performed utilizing <br /> ' wells MW-1, MW-2A, MW-3A, MW-5A, MW-6B, MW-7B, MW-8A, MW-9A, and MW-10 <br /> as required by the MRP; depth to groundwater was measured; pH, temperature, DO <br /> and ORP were measured down-hole in non-CMT wells and from purge water in CMT <br /> wells. <br /> • Depths to groundwater ranged between 19.26 feet (MW-8A) btoc and 21.87 feet <br /> (MW-1) btoc (Table 1). Groundwater elevations at the site ranged between 8.10 <br /> feet (MW-10) below NAVD88 and 11.21 feet (MW-1) below NAVD88. <br /> • pH was measured between 6.51 and 7.84; temperature was measured between <br /> ' 22.0 and 26.6 degrees Celsius; DO was measured between 2.53 and 7.84 mg/I; <br /> and ORP was measured between -8.0 and 187.4 mV. Results of YSI Multi- <br /> Parameter Meter data is presented in Table 3. <br /> ' Advanced GeoEnvironmental Inc. <br />