Laserfiche WebLink
' BACKGROUND INFORMATION <br /> Fernando's Place <br />' 1201 South Center Street, Stockton, California <br /> The site is located at the intersection of Jackson Street,French Camp Road and South Center Street <br />' <br /> (Figure 2 and was the former location of a gasoline service station The site 1s occupied currently <br /> � g )� g <br /> by several buildings, including a small-engine repair facility and a single-story, multi-family <br />' residence <br />' PREVIOUS SITE ASSESSMENT <br /> According to Work Plan -Phase 2 Site Investigation, 1201 S Center Street, Stockton, CA, dated 28 <br />' May 1999, prepared by Foothill Engineering (FE), two five-hundred gallon and one 8,500-gallon <br /> gasoline underground storage tanks (UST 1, UST 2 and UST 3, respectively) were removed from <br /> the site by Jim Thorpe Oil on 26 October 1994 Ten soil samples were analyzed from the excavation <br />' soil stockpile, the UST excavations and the product piping by GeoAnalytical Labs Each sample <br /> contained detectable concentrations of petroleum hydrocarbon contamination FE reported that the <br /> highest concentrations were located near the west end of UST 3 (Figure 2) The excavation was <br />' backfilled to surface grade following sample collection <br /> On 28 April 1998, soil boring PB1 was advanced near UST 1 and UST 2 to a depth of 30 feet below <br /> surface grade (bsg) for the collection of soil samples Analyzed samples contained concentrations <br /> of total petroleum quantified as gasoline (TPH-g) as high as 14,100 milligrams per kilogram <br /> (mg/kg) Additionally, samples were collected from the soil boring for MW-1,installed on 28 April <br /> 1998 Analyzed samples from MW-1 contained high concentrations ofTPH-g andbenzene,toluene, <br /> ethylbeneze and total xylenes (BTEX) compounds to a depth of approximately fifty feet bsg <br /> Four additional ground water monitoring wells were installed by FE between 08 and 12 March 1999 <br /> Analyzed soil samples collected from monitoring well soil borings contained detectable <br /> t concentrations of TPH-g to depths as great as 105 feet bsg and BTEX compounds to depths as great <br /> as 120 feet bsg Figure 2 illustrates monitoring well and former UST locations <br />' Between 14 and 21 August 2001, Advanced Geo Environmental Inc (AGE) advanced six Cone <br /> Penetrometer Testing(CPT)bonngs on-and off-site to depths between 122 and 175 feet bsg Based <br /> on data collected from the CPT borings, AGE identified four potential hydrogeologic units (First <br />' Water Zone, Second Water Zone, Third Water Zone and Fourth Water Zone) Significant <br /> concentrations of TPH-g, BTEX and 1,2-DCA compounds were detected in grab ground water <br /> samples collected from each of the hydrogeologic units <br /> ADDITIONAL MONITORING WELL INSTALLATION <br />' Between, 27 August and 10 October 2002, AGE prepared for and advanced seven soil borings for <br /> collection of soil samples and/or installation of monitoring wells (MW-4 through MW-9) Screen <br /> intervals were installed at the following intervals 20 to 40 feet bsg, 115 to 120 feet bsg, 141 to 146 <br />