My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2004 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:21:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2008
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY DATE J <br /> P R# <br /> VIRONMENTAL HEALTH DEPAR'► :NT PAGE Z <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK (UST)-PROGRAM INSPECTION REPORT <br /> Facility Name-,!5 (jOff:;I(t? -Facility AddressZ�8 <br /> Facilty Contact�,OW:�� ,SC 7 Title Phone #C?Z.r) zf-,69- ;?r-;o6UST# Product F.Ul, UST# ?-Product Ftj G-, # <br /> Product MUL—UST# Product <br /> Overfill Prevention: YAudible/Vis al 11 Mechanical Monitoring Panel: -A TLS- V3QZ.— <br /> Piping System: El Gravity I�Pressure ❑ Suction / Violations: ElM1-RDet ElM2-Rprev 11M3-Both <br /> Automatic Pum Shut Down Satisfies CCR 2636 (f)(5): fl Yes ❑ No Designated Operator: <br /> INSPECTION TYPE: ❑Routine ❑Monitoring Certification ❑Complaint ❑Install ❑Removal ❑Repair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: PHONE: <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 23 CCR 2643 (d) Daily monitoring of suction <br /> 2�-CCR 2637 Secondary cont. testing piping (pre-1/1/84) <br /> 3 CCR 2711(b) & (c) Current State Forms A& B 24 CCR 2636 (a) Conventional suction piping <br /> 4 HSC 25292.2 Certification of financial shall have continuous <br /> responsibility& CFO letter monitoring &20 containment <br /> 5 CCR 2632 (c)(2) UST monitoring is present (M1) 25 CCR 2643 (e) Biennial tightness test of gravit, <br /> 6 CCR 2630 (d) UST system monitoring piping (pre-1/1/84) <br /> equipment is properly located to 26 CCR 2.643 (d) Triennial line test for <br /> detect a leak (M1) conventional suction (pre- <br /> 7 CCR 2637(b) UST system monitoring 1/1/84) (M1) <br /> equipment is operational (M1) 27 CCR 2661 Permit to repair UST system <br /> 8 CCR 2636 (f)(1) Continuous monitoring system 28 HSC 25286 (a) Permit to alter monitoring <br /> for underground piping & UDC system <br /> is present(M1) 29 HSC 25298 (a) Illegal abandonment of UST <br /> 9 CCR 2636 (c)(1) All releases in secondary piping system <br /> flow to a collection sump 30 HSC 25298 (b) Permit to temporarily close US- <br /> 10 HSC 25291 (f) Line leak detector(s) (M1) system <br /> 11 HSC 25291(a)(2) Secondary containment for 31 HSC 25298 (c) Permit to close UST system <br /> UST is tight 32 HSC 25292.1 UST system is operated to <br /> 12 CCR 2635 (b)(1) Spill container (M2) prevent unauthorized release <br /> 13 HSC 25284.2 Annual spill container testing 33 CCR 2650 Recording/reporting <br /> 14 CCR 2635 (b)(2) Overfill prevention system (M2) unauthorized release (M1) <br /> 15 CCR 2631 (a) Primary containment is product-. 34 HSC 25291 (e) Water in 20 cont analyzed and <br /> tight properly disposed of <br /> 16 CCR 2632 (d) Monitoring & response plan 35 CCR 2640 (e) Single wall component within <br /> 17 CCR 2712 (i) Monitoring & response plan is 1000' of Public Well, no ELD <br /> on site 36 CCR 2635(a)(2)(A)Cathodic protection testing & <br /> 18 CCR 2712 (b) Maintenance & monitoring 60 day inspection log (M2) <br /> records (M1) 37 H&SC 25299(a)(9)Disabling leak detect. Devices <br /> 19 CCR 2636 (f)(4) Annual line tightness test 38 CCR 2715(x) Statement from UST owner <br /> 20 CCR 2630 (d) Annual line leak detector test 39 CCR 2715(c) Monthly inspection by D.O, <br /> (M1) 40 CCR 2715 (f) D.O. trained employees <br /> 21 CCR 2630 (d) Annual monitoring certification 41 Violation(s) not listed above <br /> 22 CCR 2661 (f) Repair for tank/piping has had <br /> tightness test M2 <br /> EHD INSPECTOR: PHONE: �G! <br /> RECEIVED BY: TITLE: <br /> Septic System: ❑Serves Z 20 persons/day ❑Receives other than sanitary waste <br /> Other Disposal Units Identified: ❑Dry wells/French Drains <br /> 1:1Units\Unit-111\UST\UST inspecbon8.19.04.DOC <br />
The URL can be used to link to this page
Your browser does not support the video tag.