Laserfiche WebLink
MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> OWT <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS USING THE FOLLOWING EQUATION <br /> DO NOT SAMPLE WELL FOR P= r2 x 7 48 x 3 <br /> DISSOLVED CONSTITUENTS where <br /> P=calculated purge volume(gallons) <br /> 7c =314 <br /> t <br /> r=radius of well casing in feet <br /> h =height of water column in feet i <br /> i <br /> EVACUATE WATER FROM WELL EQUAL TO i <br /> WELL EVACUATED TO PRACTICAL LIMITS THE CALCULATED PURGE VOLUME WHILE f <br /> OF DRYNESS BEFORE REMOVING MONITORING GROUNDWATER l <br /> CALCULATED PURGE VOLUME STABILIZATION INDICATOR PARAMETERS ; <br /> (pH, CONDUCTIVITY,TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME <br />• NO <br /> YES <br /> S <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER 1 <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA WELL RECHARGES TO A LEVEL <br /> pH =± 0 1 pH units SUFFICIENT FOR SAMPLE <br /> COND =t 10% COLLECTION WITHIN 24 HOURS <br /> TEMP =t I 0°F OF EVACUATION TO DRYNESS <br /> YES NO YES NO <br /> WELL PURGING CONTINUE PURGING, EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET, ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING <br /> STABILITY SAMPLING <br /> M(` FIGURE <br /> EMCMONITORING WELL PURGING PROTOCOL A-1 <br />