MONITORING WELL PURGING PROTOCOL <br /> EMCON MEASURE AND RECORD DEPTH TO WATER <br /> A31 oc lu7EA AND WELL TOTAL DEPTH <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS USING THE FOLLOWING EQUATION. <br /> DO NOT SAMPLE WELL FOR P. Ti r 2 h x 7 48 x 3 <br /> DISSOLVED CONSTITUENTS_ <br /> where <br /> P = calculated purge Volume(gattons) <br /> rt - 314 <br /> r = radius of well casing in feet <br /> h = height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL. LIMITS THE CALCULATED PURGE VOLUME WHILE <br /> OF DRYNESS BEFORE REMOVING MONITORING GROUND-WATER STABILIZATION <br /> CALCULATED PURGE VOLUME INDICATOR PARAMETERS(pH. CONDUCTIVITY, <br /> TEMPERATURE)AND TURBIDITY AT INTERVALS <br /> OF ONE CASING VOLUME <br /> NO 1 YES <br /> FINAL TWO SETS OF GROUND-WATER <br /> STABILIZATION INDICATOR PARAMETER WELL RECHARGES TO A LEVEL <br /> MEASUREMENTS MEET THE FOLLOWING SUFFICIENT FOR SAMPLE <br /> CRITERIA COLLECTION WITHIN 24 HOURS <br /> COND 10 °Yo <br /> Pt 0 1 pH tsnrts OF EVACUATION TO DRYNESS. <br /> = t <br /> TEMP = + 10 °F <br /> YES NO <br /> YES I,IO -- 2 <br /> FIELD TEST FIRST RECORD WELL <br /> WELL PURGING CONTINUE PURGING, RECHARGE WATER FOR AS DRY FOR <br /> CRITERIA MET, EVACUATE ADDITIONAL INDICATOR PARAMETERS PURPOSES OF <br /> PROCEED TO CASING VOLUME OF j AND TURBIDITY,THEN SAMPLING. <br /> WELL SAMPLING WATER. MONITORING PROCEED TO WELL <br /> INDICATOR PARAMETERS SAMPLING <br /> FOR STABILITY <br /> EM C O N lHauRE <br /> Associates <br /> MONITORING WELL PURGING PROTOCOL [ Aml <br />