Laserfiche WebLink
r&Eseeo <br /> A Corning Companv <br /> I Sample Description <br /> See the attached Sample Description Information. <br /> The samples were received under chain-of-custody. <br /> I1 Analysis Reguest <br /> The following analytical tests were requested. <br /> Lab ID Analysis Description <br /> 059500-1 thru 4 Sample Composite <br /> -5 Total Petroleum Hydrocarbons and BTEX <br /> Lead <br /> III Quality Control <br /> A. Project Specific OC. No project specific QC (1 .e. , spikes and/or <br /> duplicates) was requested. <br /> B. Method Blank Results. A method blank is a laboratory-generated <br /> sample which assesses the degree to which laboratory operations <br /> and procedures cause false-positive analytical results for your <br /> samples. <br /> No target parameters were detected in the method blanks associated <br /> with your samples at the reporting limit levels noted on the <br /> attached Method Blank Report. <br /> C. Laboratory Control Samples - The US Program <br /> Duplicate Control Samples. A DCS is a well -characterized matrix <br /> (blank water, sand or ceiite) which is spiked with certain target <br /> parameters and analyzed at approximately 10% of the sample load in <br /> order to establish method-specific control limits. The DCS <br /> results associated with your samples are on the attached Duplicate <br /> Control Sample Report. <br /> Accuracy is measured by Percent Recovery as in: <br /> % recovery = measured concentration) x 100 <br /> (actual concentration) ^ <br /> Precision is measured using duplicate tests by Relative Percent Difference <br /> (RPD) as in: <br /> RPD = (% recovery test 1 recovery test 2) x 100 <br /> (% recovery test 1 t % recovery test 2)/2 <br />