Laserfiche WebLink
F <br /> ❑ The elevated reporting limits were the result of dilutions performed by the laboratory in order to quantitate a target anal31e(s); <br /> Q The elevated reporting limits reported in the Method <br /> analysis of samples <br /> were due to presence of <br /> in these samples. <br /> O The reported results for GRO/DRO in samples <br /> have been confirmed as gasoline/diesel. <br /> t7 The reported results for GRO/DRO in samples <br /> is/are due to <br /> peaks present in the gasoline quantitation range, however, the peaks present do not resemble the chromatographic <br /> he pattpatternor gasoline. <br /> ❑ The reported results for GRO/DRO in samples <br /> is/are due to a discrete peals in the C -C_range(probably <br /> L) The reported results for ' <br /> i <br /> in samples <br /> be considered estimated because the associated continuing calibration standard should <br /> was outside of acceptance criteria. i <br /> ❑ The reported results for <br /> in samples <br /> be biased low because the associated continuing calibration standard was outside of acceptance criteria. may <br /> a The reported results for <br /> in samples <br /> be biased high because the associated continuing calibration standard was outside of acceptance criteria. may <br /> ❑ The reported results for <br /> in samples <br /> may be biased low since the analyses <br /> for these analytes were performed days beyond the U.S.EPA recommended holding time of days. i <br /> ❑ The reported results for in samples <br /> may be biased low/high as demonstrated by a low/high surrogate recovery due to matrix interference. <br /> ❑ The reported results for in samples <br /> should <br /> be considered estimated due to a high relative percent difference reported between the associated LCS and LCSD. <br /> ❑ The reported results for in samples <br /> may <br /> be biased lowthigh due to a lowlhigh average percent recovery reported in the associated MS/MSD analysis. <br /> ❑ The reported results for in samples may <br /> t <br /> Y <br /> be biased low/high due to a low/high average percent recovery reported in the associated MS/MSD analysis. <br /> ❑ The reported results for <br /> in samples <br /> should <br /> I <br /> be considered estimated because the primary and confirmation column results differed by greater than 40%RPD. <br /> ❑ The reported results for in samples t <br /> P should be <br /> considered estimated; the samples were initially analyzed within holding time but required dilution. The dilution was <br /> performed out of holding time. <br />