Table 4 <br /> Groundwater Analytical Results <br /> Chevron Service Station#9-2033 <br /> 508 West Charter Way <br /> Stockton,California <br /> EXPLANATIONS <br /> Groundwater monitoring data and laboratory analytical results prior to May 31,2000,were compiled from reports prepared by Blaine Tech Services,inc <br /> 1,2-DCA= 1,2-Dichloroethane Cd=Cadmium Pb=Lead <br /> (ppb)—Parts per billion Cr=Chromium Zn=Zmc <br /> TOG=Total Oil and Grease Ni=Nickel --=Not Analyzed <br /> I <br /> 2-Methylnaphtalene and Naphthalene were 8 7 and 33 ppb respectively <br /> 2 2-Methylnaphtalene and Naphthalene were 8 7 and 50 ppb respectively <br /> 3 Naphthalene was detected at 34 ppb <br /> 4 2-Methylnaphtalene and Naphthalene were 5 3 and 35 ppb respectively <br /> 5 Diethylphthalate was detected at 6 9 ppb <br /> 6 Naphthalene was detected at 6 8 ppb <br /> 7 All other Semivolatile Organic Compounds(SVOCs)by EPA Method 8270 were ND,except for Bis(2-ethylhexyl)phthalate was detected at 27 ppb <br /> 8 All other Volatile Organic Compounds(VOCs)by EPA Method 8010 were less than the reporting limit <br /> 9 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethylhexyyl)phthatate was detected at 12 ppb <br /> 10 All other VOCs by EPA Method 8010 were less then the reporting limit,except for Chloroform which was detected at 17 ppb <br /> 11 Laboratory report indicates that this sample was analyzed outside of the EPA recommended holding time <br /> 12 All sample containers were broken on this date <br /> 13 All other VOCs by EPA Method 8021 were less then the reporting limit <br /> 14 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethylhexyl)phthatate was detected at 71 ppb <br /> 15 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 26 ppb <br /> i <br /> 16 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 13 ppb <br /> 17 All other SVOCs by EPA Method 8270 were less than the reporting limit <br /> 18 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 23 ppb,and Chloroform at 1 ppb <br /> 19 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Chloroform was detected at 15 ppb <br /> 20 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Diethylphthalate was detected at 2 ppb and bis(2-Ethylhexyl)phthalate was detected at 16 ppb <br /> 21 All other SVOCs by EPA Method 8270 were les,,than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 7 ppb <br /> 22 Laboratory report indicates this sample was extracted past the 7 day holding time for TPH <br /> 23 All other SVOCs by EPA Method 8270 were les,,than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 4 ppb <br /> 24 All other SVOCs by EPA Method 8270 were les,,than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 2 ppb <br /> 25 All other SVOCs by EPA Method 8270 were les,,than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 3 ppb <br /> 9-203386847is �1/07/05 <br />