Laserfiche WebLink
Table 1 <br /> Groundwater Monitoring Data and Analytical Results <br /> Chevron Service Station #9-2033 <br /> 508 West Charter Way <br /> Stockton,California <br /> EXPLANATIONS (cont) <br /> ' Laboratory report indicates hydrocarbon pattern is present in the requested fuel quantitation range but does not resemble the pattern of the requested <br /> tuel The pattern more closely resembles that of a heavier hydrocarbon mix <br /> 22 All other VOCs by EPA Method 8021 were less then the reporting limit <br /> 21 All other SVOCS by EPA Method 8270 were less than the reporting limit,except for B i s(2-ethylhexyl)phthal ate was detected at 71 ppb <br /> 24 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethyihexyl)phthalate was detected at 26 ppb <br /> '-` All other SVOCs by EPA Method 8270 were less than the reporting limit except for Bis(2-ethylhexyl)phthalate was detected at 13 ppb <br /> 26 BTEX and MTBE by FPA Method 8260 <br /> 27 All other SVOCs by EPA Method 8270 were less than the reporting limit <br /> 2a All other SVOCs by EPA Method 8270 were less than the reporting limit except for Bis(2-ethyl hexyl)phth alate was detected at 23 ppb,and Chloroform at 1 ppb <br /> 29 All other SVOCs by EPA Method 8270 were less than the reporting limit except for Chloroform was detected at 15 ppb <br /> '0 All other SVOCS by EPA Method 8270 were less than the reporting limit except for Diethylphthalate was detected at 2 ppb and bis(2-Ethylhexyl)phthalate was detected at 16 ppb <br /> 1i All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethylhexyl)phthalate was detected at 7 pph <br /> 12 Laboratory report indicates this sample was extracted past the 7 day holding time for TPH <br /> ii Ail other SVOCs by EPA Method 8270 were less than the reporting limit except for Bis(2-ethylhexyl)phthalate was detected at 4 ppb <br /> 14 All other SVOCs by EPA Method 8270 were less than the reporting limit,except for Bis(2-ethyl hexyl)phthalate was detected at 2 ppb <br /> " All other SVOCs by EPA Method 8270 were less than the reporting limit except for Bis(2-ethyl hexyl)phthalate was detected at 3 ppb <br /> 9-2033 86847 . A0/09/05 <br />