Laserfiche WebLink
Lancaster - Report <br /> Laboratories �t n a l ys 1s <br /> 5 New Holland Pike PO Box 12425 Lancaster PA 17605-2425•717-656 2300 Fax 717 656 2681•www lancasterlabs com <br /> Page 6 of 7 <br /> Quality Control Summary <br /> Client Name ChevronTexaco Group Number 884689 <br /> Reported 02/23/04 at 04 21 PM <br /> Surrogate Quality Control <br /> Batch number 04045WAF026 <br /> 2-Fluorophenol Phenol-d6 2,4,6-Tribromophenol Nitrobenzene-d5 <br /> 4216136 53 35 94 85 <br /> Blank 56 40 94 86 <br /> LCS 60 42 93 87 <br /> MS 59 41 89 86 <br /> MSD 60 41 89 89 <br /> Limits 23-94 10-80 45-142 54-124 <br /> 2-Fluorobiphenyl Terphenyl-d14 <br /> 4216136 82 70 <br /> Blank 8o 85 <br /> LCS 86 94 <br /> MS 87 8'7 <br /> MSD 88 92 <br /> Limits 64-112 53-124 <br /> Analysis Name TPH - DRO CA LUFT (Waters) <br /> Batch number 040470024A <br /> Orthoterphenyl <br /> Wa6136 93 <br /> nk 92 <br /> LCS 110 <br /> LCSD 112 <br /> Limits 59-139 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 04047A16A <br /> Trifluorotoluene-F <br /> 4216135 116 <br /> Blank 116 <br /> LCS 116 <br /> LCSD 114 <br /> Limits 57-146 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 04049A07A <br /> Trifluorotoluene-F <br /> 4216136 74 <br /> Blank 78 <br /> LCS 94 <br /> MS 96 <br /> MSP 95 <br /> Limits 57-146 <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 04049A07B <br /> Trifluorotoluene-F <br /> *-Outside of specification <br /> �) The result for one or both determinations was less than five times the LOQ <br /> The background result was more than four times the spike added <br />