Laserfiche WebLink
r r r r a" r r sr sr <br /> 4rD1 W W* <br /> Treatment System Performance Data <br /> The Transmission Shop <br /> 515 West Charter Way <br /> Stockton,California <br /> Field TPH as Gasoline Benzene <br /> FID Reading <br /> Hour Meter Percent Blower Flow Rate Total System Influent Net Removed Influent Net Removed <br /> Site Visit Reading Operational Vacuum at Manifold Flow Rate Influent Effluent Concentration Removed` to Date Concentration Removed* to Date <br /> Date Description Comments (hours) N ("H20) (scfm) (scfm) (ppmv) (ppmv) (mg/m3) (pounds) (pounds) (mg/m3) (pounds) (pounds) <br /> 12/30/02 O&M shut down NA NA 68 43 35 2 2 - NA 3,165 — NA 45 <br /> REPORTING PERIOD SECOND QUARTER 2002 ? <br /> POUNDS REMOVED SINCE STARTUP 3,165 4 5 <br /> GALLONS REMOVED SINCE STARTUP 519 06 <br /> TPH=Total petroleum hydrocarbons Total system flow rate accounts for the flow after dilution <br /> "H2O= Inches of water Density of benzene=7 34 pounds per gallon <br /> scfm=Standard cubic feet per minute Density of gasoline=6 1 pounds per gallon <br /> ppmv=Parts per million by volume *=Since last hour meter reading <br /> NA=Not available or not applicable **=Analytical result not available at time of report preparation <br /> n/ Ll [ <br /> I <br /> 8800391A1Quarterly14g021SvedatalTABLE 1 Page 4 of 4 1128103 <br />