Laserfiche WebLink
WELL COIONTRATIONS <br /> Shell-branded Service Station <br /> 620 West Charter Way <br /> Stockton, CA <br /> MTBE MTBEJ Depth to GW SPH DO <br /> Well ID Date TPPH B T E X 8020 8260 TOC Water Elevation Thickness Reading <br /> u ILu /L u IL u IL u IL u 1L u IL MSL ft MSL ft m <br /> Notes <br /> *= Field data sheets for this event misplaced, no field measurements available for this event <br /> **=MTBE confirmed, Benzene did not confirm by GOMS <br /> a=Analysis was run past recommended hold time <br /> b= Result was generated out of hold time <br /> c=TPPH analyzed by modified EPA Method 8015 and BTEX analyzed by EPA Method 8020 <br /> d= Insufficient water to record measurement <br /> e=Top of casing elevation altered during wellhead maintenance <br /> f=Site wells surveyed to mean sea level on February 20, 2002, by Virgil Chavez Land Surveying of Vallejo, California Previous elevations referenced to site datum <br /> When separate-phase hydrocarbons are present,ground water elevation is adjusted using the relation <br /> Corrected ground water elevation=Top-of-casing elevation-depth to water+(0 8 x hydrocarbon thickness) <br /> i <br /> Page 21 <br />