Laserfiche WebLink
ciao KEY TO RESULT FLAGS <br /> * RPD between sample duplicates exceeds 30% <br /> *M RPD between sample duplicates or MS/MSD exceeds 20t <br /> + Correlation coefficient for the Method of Standard Additions is less than o 995 <br /> c Sample result is Less than reported value <br /> B-I - Value is between Method Detection Limit and Reporting Limit <br /> B-0 Analyte found in blank and sample <br /> C The result confirmed by secondary column or GCIKS analysis. <br /> CNA Cr+6 not analyzed; Total Chromium concentration below Cr+6 regulatory level <br /> comp sample composited by equal volume prior to analysis <br /> D- The result has an atypical pattern for Diesel analysis <br /> Dl ; The result for Diesel is ars unknown hydrocarbon which consists of a single peak. <br /> DH : The result appears to be a heavier hydrocarbon than Diesel. <br /> DL The result appears to be a lighter hydrocarbon than Diesel <br /> DR Elevated Reporting Limit due to Matrix <br /> DS Surrogate diluted out of range. <br /> DX. The result for Diesel is an unknown hydrocarbon which consists of several peaks. <br /> FA _ Compound quantitated at a 2X dilution factor <br /> FB Compound quantitated at a 5X dilution factor <br /> FC Compound quantitated at a lox dilution factor <br /> FD Compound quantitated at a 20x dilution factor <br /> FE Compound quantitated at a SOX dilution factor <br /> FF Compound quantitated at a lOOX dilution factor <br /> FG Compound quantitated at a 20OX dilution factor <br /> FH Compound quantitated at a 50OX dilution factor <br /> FI Compound quantitated at a 1000X dilution factor <br /> FJ Compound quantitated at a greaten' than 1000x d2.1ution factor <br /> FK Compound quantitated at, a 25X dilution factor <br /> FL Compound quantitated at a 25OX dilution factor. <br /> G- The result has an atypical pattern for Gasoline. <br /> G1 The result for Gasoline is an unknown hydrocarbon which consists of a single peak. <br /> GH The result appears to be a heavier hydrocarbons than Gasoline <br /> GL The result appears to be a lighter hydrocprbon than Gasoline. <br /> GX The result for Gasoline is an unknown hydrocarbon which consists of several, peaks <br /> HX : Peaks detected within the quantitation range do not match standard used. <br /> j Value is estimated. <br /> M1 Matrax xnterfezence Suspected. ' <br /> MSA Value determined by Method of Standard Additions <br /> MSA* : Value obtained by Method of Standard Additions, Correlation coefficient is c0_ 995 <br /> UZI : Sample spikes outside of QC limits; matrix interference suspected <br /> U12 : sample concentration is greater than 4X the spiked value; the spiked value is <br /> considered insignificant. <br /> H13 : Matrix Spike values exceed established QC limits, post digestion spike is in <br /> control. <br /> P7 pH of .sample > 2; sample analyzed past 7 days <br /> RSC : Refer to subcontract laboratory report for QC data. <br /> S2 : Matrix interference confirmed by repeat analysis. <br /> gCH : Thiocyanate not analyzed separately; total value is below the Reporting Limit for <br /> Free Cyanide. <br /> umm : Undetected at the Method Detection Limit. <br /> r� <br />