Laserfiche WebLink
Site Background Information K & S Gas & Grocery <br /> Page 2 of 5 <br /> detected at a depth of 45 feet bsg or in samples analyzed from the three other borings Soil probe <br /> boring installations were described in theAGE-prepared Preliminary Site Assessment Report in <br /> August 1997 <br /> One 20,000-gallon UST was installed at the site following the 1998 UST removals Approximately <br /> 341 tons of hydrocarbon-impacted soil were excavated during removal of the old USTs and over- <br /> excavation for the installation of the new UST and piping Soil was disposed of at Forward Landfill <br /> During the UST installation, two conductor casings were installed through the pea gravel adjacent <br /> to the UST in anticipation of future site assessment needs The UST removal, over-excavation,and <br /> UST installation were described in the AGE-prepared UST Removal Report, dated 26 May 1998 <br /> Three ground water monitoring wells (MW-1 through MW-3)were installed in December 1998 as <br /> part of site assessment activities Petroleum hydrocarbon-impacted soil was encountered in all well <br /> borings The maximum concentration of TPH-g was 4,200 mg/kg (MW-1) Benzene and MTBE <br /> were detected only in soil sample MW2-35 at 0 0058 mg/kg and 0 011 mg/kg, respectively <br /> TPH-g was detected in initial ground water samples collected from MW-1 through MW-3 at a <br /> maximum concentration of 330,000 micrograms/liter (µg/1) in the sample from MW-3 BTEX <br /> . compounds were detected at concentrations as high as 29,000 µg/1 benzene, 54,000 µg/1 toluene, <br /> 6,500 µg/1 ethylbenzene, and 36,000 µg/1 xylenes (MW-3) MTBE was detected in all three well <br /> samples at a maximum concentration of 510 µg/1(MW-1) In addition,TBA was detected in MW-1 <br /> and MW-2 at a maximum concentration of 83 0µg/1(MW-1) Monitoring well installation and initial <br /> monitoring activities were described in the AGE-prepared Monitoring Well Installation Report, <br /> dated 02 June 1999 <br /> Between February and November 2001,AGE advanced five paired cone penetrometer testing(CPT) <br /> soil borings(CPT-1 through CPT-5)at the site to depths between 100 feet and 150 feet bsg to assess <br /> the extent of petroleum hydrocarbon impact and to identify potential hydrologic units TPH-g was <br /> detected in grab ground water samples at concentrations as high as 14,000 µg/1 (CPT-4), BTEX <br /> compounds were detected at concentrations as high as 4,000 µg/1 (benzene, CPT-4), MTBE was <br /> detected at concentrations as high as 13 pg/l (CPT-4), TBA was detected at concentrations as high <br /> as 5 0 gg/1 (CPT-2) <br /> Based on CPT data,AGE developed a hydrogeologic model for the site consisting of a vadose zone <br /> and six potential hydrologic units informally identified as Hydrologic Unit 1 (HUI), located <br /> between 30 feet and 70 feet bsg,Hydrologic Unit 2 (HU2), located between 70 feet and 85 feet bsg, <br /> Hydrologic Unit 3 (HU3), located between 85 feet and 95 feet to 100 feet bsg, Hydrologic Unit 4 <br /> (HU4), located between 95 feet to 100 feet and 120 feet bsg, Hydrologic Unit 5 (HUS), located <br /> between 120 feet and approximately 135 feet bsg, and Hydrologic Unit b (HU6), located between <br /> • 135 feet and at least 150 feet bsg Geologic cross sections A A' and B-B'were generated from the <br /> CPT data, depicting the informal hydrologic units and petroleum hydrocarbon concentrations <br /> Advanced GeoEnvironmental,Inc <br /> 1 <br />