Laserfiche WebLink
f0t unit requirements continued; <br /> 642-1-0 <br /> gage 2 <br /> 12 The soil remediation system shall not be operated unless the combustion chamber is at or above the <br /> minimum operating temperature. The system shall automaticall terminate operation if the temperature drops <br /> below the minimum operating temperature (District Rule 2201 <br /> 13. The minimum operating temperature for the combustion chamber of the thermal oxidizer shall be 1400 <br /> degrees F (District Rule 2201] <br /> 14. The total VOC emission rate from the soil remediation system served by the thermal oxidizer shall not <br /> exceed 12 6 pounds in any one day. [Distract Rule 2201] <br /> 15 Only natural gas sliall be used as auxiliary fuel for the combustion of VOC. [Distnct Rule 2201] <br /> 16. The total NOx emission rate from the soil remediation system served by the thermal oxidizer Shall not <br /> exceed 0.1 lb/MMBTU [District Rule 22011 <br /> 17. The total CO emission rate from the soil remediation system served by the thermal 0XI(h7er Shall not <br /> exceed 0.021 lb/IVtMgl-J [District Rule 22011 <br /> 0 <br /> 1 hese terms and conditions are part of the �.,,ill(pAide Permit to operate. <br />