My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
814
>
3500 - Local Oversight Program
>
PR0544222
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2019 2:07:09 PM
Creation date
3/5/2019 11:47:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0544222
PE
3528
FACILITY_ID
FA0005976
FACILITY_NAME
TIRE & WHEEL MASTERS
STREET_NUMBER
814
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16718101
CURRENT_STATUS
02
SITE_LOCATION
814 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
195
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> I rr ) <br /> Messrs Trommer and.Lai 19 June 2008 <br /> ' Preliminary Five-Year Review Letters Page 3 of 7 <br /> Various Sites <br /> 1645 Cherokee Road. <br /> • The CUF concurs with the EHD directive and work plan approval for additional <br /> site assessment and recommended conducting regular quarterly monitoring and <br /> uploading existing data to GeoTracker; the EHD has directed these actions. <br /> 440 Charter Way, W. <br /> • The CUF has recommended that the EHD issue'_directives to assess remedial <br /> groundwater technologies and implement active groundwater remediation without <br /> delay. The EHD intends to issue such directives after the second monitoring <br /> event that includes these new wells has been reported and reviewed to better <br /> tailor the directives to site conditions. <br /> 2905 and 2908 Benjamin Holt Drive. <br /> • The CUF has recommended that the remediation systems continue to operate to <br /> achieve WQOs in a timely manner. The sites are not currently under active <br /> remediation, the consultant notes in their reports that the remediation method is <br /> natural attenuation, which the EHD has not approved as the appropriate <br /> remediation method at this time. A municipal well is within 300 feet of one of the <br /> sites and in the past the municipal well has been impacted by the plume; <br /> monitoring wells down-gradient of the municipal well are currently impacted. The <br /> monitoring wells on the Chevron station were destroyed during a station rebuild <br /> and were later reinstalled; with receipt and review of the fourth quarterly <br /> monitoring event on the new wells, the EHD plans to review all data and issue <br /> directives related to remediation requirements. <br /> 2050 Fremont Street, E. <br /> • The CUF has recommended that the EHD direct the RP to define the extent of <br /> contamination, assess remedial technologies, andimplement active remediation <br /> that will achieve WQOs in a timely manner; the EHD agrees with these <br /> recommendations and notes that directives have been issued. <br /> 602 California Street, N. <br /> • The CUF has recommended that the EHD direct assessment of remedial <br /> technologies and implement active remediation without delay;.the EHD agrees <br /> with these recommendations. A feasibility study has been directed, SVE has <br /> been tested and found to be an effective technology to remediate impacted soil <br /> and the EHD approved preparation of.a work plan to install an SVE system; the <br /> i consultant then -recommended DPE without a ;technical justification. As a <br /> technical justification has not been provided after having been requested in <br /> writing, the EHD has issued a directive to submit a work plan for SVE. A report of <br /> findings for recently installed monitoring wells is pending. <br /> 1112 Harding Way, E. <br /> • The CUF has recommended that the EHD direct the RP to assess remedial <br /> technologies that may achieve WQOS more rapidly; the EHD agrees with this <br /> 5-Year Review Comment Letter 061908.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.