WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2004 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 11:39:42 AM
Creation date
3/7/2019 9:33:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2006
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> F se By All Jurisdictions Within the State of California <br /> Authority Cited.Chapter 6.7,h and Safety Code;Chapter 16, Division 3 Title 23, Cali, Code of Regulations <br /> This-form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certfication or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ARCO/B.P.#5469,CC 18022648 City: STOCKTON CA Zip:95205 <br /> Site Address: 130 S.WILSON WAY Contact Phone No: 466-6633 <br /> Date of Testing/Service: 04/18/2006 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:V.R.TLS-350 Work Order Number: 2242204 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1-87 Tank ID: 2-89 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 409 Annular Space or Vault Sensor. Model: 409 <br /> 71 Piping Sump/Trench Sensor(s). Model: 323 X Piping SumprTrench Sensor(s). Model: 323 <br /> X Fill Sump Sensor(s). Model: 323 323 <br /> Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: CPT <br /> X Electronic Line Leak Detector. Model: PLLD <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: Tank ID: <br /> X In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 409 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 323 Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 323 Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector- Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: PLLD <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Others <br /> ( pedfy equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> 0 Dispenser Containment Sensor(s) Model:323 X Dispenser Containment Sensor(s) Model:323 <br /> X❑Shear Valve(s). X Shear Valve(s) <br /> ElDispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> X❑ Dispenser Containment Sensor(s) Model:323 Dispenser Containment Sensor(s). Model:323 <br /> XD Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/12 Dispenser ID: 13/16 <br /> ❑X Dispenser Containment Sensor(s) Model:323 X Dispenser Containment Sensor(s). Model:323 <br /> OShear Valve(s). X Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Cham(s). ElDispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): ❑System set-upX❑Alarm history report <br /> Technician Name(print): JOEY MESA Signature: <br /> Certification No.: 006-05-1532 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 04/18/2006 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.