Laserfiche WebLink
UNDERGROUND STORAGE TANK <br />MONITORING PLAN - PAGE 2 <br />. ` � , DISPENSER 7YIOTORING <br />MONITORING OF AREAS BENEATH DISPENSERS) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) Myo. <br />® 1. CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) <br />PANEL MANUFACTURER: Veeder Root MSL MODEL #: TLS 350 M52. <br />LEAK SENSOR MANUFACTURER: Veeder Root MS3 MODEL #(S): 794380-323 M54. <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ® a. YES ❑ b. NO Mss. <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a. YES ❑ b. NO M56. <br />WILT, FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a. YES ❑ b. NO M57. <br />❑ 2. MECHANICAL ASSEMBLY (e.g., FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: M"- MODEL #(S): M59. <br />❑ 3.VISUAL MONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY (Requires agency approval) M60. <br />❑ 4. NO DISPENSERS <br />❑ 99. OTHER (Specify) M6I <br />VII:. ENHANCED LEAK- DETECTION <br />❑ 1. WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70. <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED** <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) Mao. <br />1. ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required)* <br />3. ® THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of MM/DD/YY) <br />4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br />�^ ❑ OTHER (Specify): M81 <br />innel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br />By 1/1/2005, this facility will have a "Designated UST Operator" who has passed the operator exam administered by the International Code Council (ICC). By July 1, <br />2005, and annually thereafter, the "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems. This training <br />will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the leak detection equipment. <br />➢ The facility employee's role with regard to spills and overfills. <br />➢ Whom to contact for emergencies and leak detection alarms. <br />For facility employees hired on or after July 1, 2005, the initial training will be conducted within 30 days of the date of hire. <br />w .,. IX. COAMENTS/ADDITIONAL INFORMATION <br />Please use this sec 'on to include any additional UST system monitoring -related information additional �` ation requiredby your local agency): Mas <br />g(eg., <br />jt oif fa ,LL N-hol =- Aaot# I v►sv4,._ f 4L,*a M , t�i+�c.i. LO"I - Sohl <br />*Monitoring systems manual maintained by contracted, licensed pump and tank technicians. <br />Best Management Practices are maintained in the H.S.S.E. Retail Facility Programs Manual (Green Binder). <br />**ELD Test Reports submitted to the San Joaquin Environmental Health Division: Report date 12/10/04 <br />X. PERSONNEL RESPONSIBILITIES <br />THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR PEFORMING MONITORING. BP WEST COAST PRODUCTS <br />LLC IS RESPONSIBLE FOR MAINTAINING AND TESTING ALL MONITORING EQUIPMENT. <br />XI OWNEIMPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />OWNER/0 ERATOR SIGN REPRESENTING DATE: M91 <br />?y <br />I-- M <br />®Operator 23 14fL <br />/ ❑ Owner M90. d / <br />M9z. <br />OWNER/OPERATOR NAME (print): <br />OWNER/OPERATOR TITLE: M93. <br />LAWRENCE WIGHT <br />DEALER <br />,icy Use Only) This plan has been reviewed and: Approved El Approved With Conditions El Disapproved <br />la -7 <br />Local Agency Signature: — r1 _ Date: 2 Z <br />Comments/Special Conditions: <br />Arco #05469, Belshire Environmental Services Page 2 of 5 <br />