Laserfiche WebLink
PACIFIC ENVIRONMENTAL SYSTEMS LLC <br /> Periodic Integrity Test Certificate <br /> P.O. Box 576231. Modesto,CA 95357 Telephone: (209) 549-2451/209-499-6692cell <br /> Email: hacificcav(ugrnail.com <br /> Client: Tiger Lines,LLC Contact : Mark Handel,Environmental Compliance Mgr. <br /> Address: 927 Black Diamond Way Phone No.: 800-967-8443 <br /> City/State/Zip; Lodi, CA 95240 Date of Test: 4-25-2019 <br /> Product Stored: Diesel Fuel Tank B <br /> Tank Information(Brand/gallonage/Fuel Stored/UL or other serial#/miscellaneous) <br /> Modern Welding/25000 gals/Diesel FucVUL2085/UL#A702553/Double Wall Steel/22 yrs ohh111995 ) <br /> Description of Secondary Containment Integral Secondary Containment <br /> Date of Test-4-25-2019 Test Supervisor(s) Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX Secondary XX <br /> I. Steel Thickness Test(in accordance with API-653 and/or STI SP001 (6a edition)-Readings Steel <br /> Thickness UL142 min. .240in./Avg Steel thickness=.332 in. as tested <br /> 2. Inert Gas Blanket <br /> Gas Used: Nitrogens CO2:_ Other(specify) <br /> Air Pressure-Test Vacuum Test XX <br /> Initial Reading (document psi/WC readings) 5Hg Time 8:20am <br /> End Readings (document psi/WC readings) 5Hg Time 9:20am <br /> Duration of Test: %drop <br /> 3. Sonar-Test Y N(document db readings) Duration <br /> 4. Camera(visual) model Lorex MC81845/interstitial (Result: PT)_-_zb�; <br /> 5. Hydro-Carbon Sensor(probe)model OMNTEC BOA- (Result: P/F) <br /> 6. Hydrology (Water Column) (inches of water column readings) <br /> Duration %Drop Results (P/F) <br /> 7. Other: Inspect Vessel &secondary containment. AST clearance is 5 inches above floor. CRDM <br /> present, Tank is Category 1 under STI-SP001 Standards. No evidence of leaking product from <br /> primary vessels stem accessible for inspection: No vroduct in secondary.U on ins ection no evidence <br /> of weld breaks,punctures,cracks,or other structural damage to the tank. No external issues affecting tank <br /> iute rit . AST is anchored to concrete floor. : PASS <br /> TEST RESULTS <br /> 150-Stage: <br /> Pass XX Fail_(quantify) SENSOR DETECTS NO PRODUCT ,NOR LEAKS FROM PRIMARY <br /> TANK INTO SECONDARY CONTAINMENT <br /> 2id-Stage: <br /> Pass XX Fail (quantify) NO VISUAL EVIDENCE OF PRODUCT IN THE SECONDARY <br /> NOR OF ANY OTHER LEAKS & STEEL THICKNESS IN EXCESS OF MINIMUM UNDER UL <br /> 142 STANDARD & NO DECAY ON VACUUM LEVELS FOR VACUUM TEST FOR 1 ITR. <br /> Comments section data on file <br /> Next Scheduled Periodic Integrity Test 4-25-2039 4-25--2039 <br /> Q yyn"- Pacific Environmental Systems,Representative <br /> STI SP001 Certified Inspector No.: AST 135013 <br />