My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 10:36:02 AM
Creation date
3/20/2019 11:10:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� PERM 200-17 <br />S. AUTOMATIC LINE LEAK <br />DETECTORS <br />Automatic line leak detectors (ALLD) are used with <br />submersible turbine pump (STP) systems to detect cata- <br />strophic leaks in pressurized product piping systems. <br />Automatic line lcak detectors may be either mechanical <br />or electronic. <br />ALLDs must be able to detect a leak in a product line that <br />is equivalent to 3 gph at 10 psig. Therefore, the test appa- <br />ratus that is utilized to conduct this test must accurately <br />simulate a leak that is equivalent to 3 gph at 10 psig. This <br />is accomplished by adjusting the size of the orifice in the <br />test apparatus until the required flow rate is achieved. <br />The calibration of the test apparatus leak orifice may be <br />accomplished either with or without the use of a pressure <br />regulator. The procedure for calibration with a pressure <br />regulator is described in Section 9.1.6. The procedure <br />for calibration without the use of a pressure regulator <br />is described in Section 9.2.6. Either procedure may be <br />used to accomplish calibration of the test apparatus leak <br />orifice. <br />NOTE: In order for a line leak detector to <br />function properly, the STP must properly <br />cycle on/off. Confirm that the STP properly <br />cycles on/off as it would during normal <br />fueling operations and visually inspect the <br />STP electrical relay switches (also known as <br />"contactors") to ensure that the contacts are in <br />good condition. If the contacts show visible <br />signs of excess arcing, damage or wear, notify <br />the appropriate person to obtain authorization <br />to replace the defective relays. If the STP <br />does not properly cycle on/off, the line leak <br />detector may not detect a leak from the pip- <br />ing, and fails the test. <br />NOTE: Piping configurations with multiple <br />STPs and manifolded lines or those systems <br />having master/satellite fuel dispensers must <br />be installed properly for automatic line leak <br />detectors to function correctly. Consult manu- <br />facturer's literature regarding proper installa- <br />tion and operation. <br />NOTE: Testing of ALLDs involves creating <br />a simulated leak from the piping system and <br />activating the STP at specific times to pres- <br />surize the system. These activities can be <br />0 pei.org <br />hazardous if done improperly. To prevent <br />unsafe conditions from developing, follow <br />the safety precautions described in Section 3 <br />and lockout/tagout procedures. <br />FIGURE 9-1. The MLLD mounted on the submersible <br />turbine pump will restrict flow when a leak is detected. <br />9.1 Mechanical Line Leak Detectors (MLLDs). <br />9.1.1 General. MLLDs are commonly installed <br />at the STP and can detect a leak in product piping <br />between the MLLD and the solenoid valve inside <br />product dispensers. MLLDs restrict product flow if <br />a leak is detected. <br />Use this test procedure in conjunction with the <br />MLLD manufacturer's installation and mainte- <br />nance instructions. <br />9.1.2 Purpose. This test method is used to <br />determine if an MLLD can detect a product line <br />leak equivalent to 3 gph at 10 psig. <br />9.1.3 Description of Test. A test apparatus is <br />typically connected to the test port of the shear <br />valve inside a dispenser to simulate a leak in the <br />product line equivalent to 3 gph at 10 psig. The <br />performance of the line leak detector is observed <br />to see if it can detect the simulated leak. <br />9.1.4 Test Equipment. Test equipment shall <br />include: <br />• test apparatus that includes a pressure gauge <br />with a minimum range of 0-60 psig, a pressure <br />regulator and an adjustable orifice that can simu- <br />late a leak rate equivalent to 3 gph at 10 psig; <br />