My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 10:36:02 AM
Creation date
3/20/2019 11:10:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities <br />ZCLa I XERXES a <br />making a lasting differenceDATA LOG <br />TRUCHEK' <br />Fill out the site location, tank information and test boxes below. Be sure to choose the correct test box according to the <br />diameter of the tank being tested. Follow the test procedures on the other side of this form. A separate test form is needed <br />for every tank. For additional copies of the form, contact the Customer Service Representative at the Xerxes manufacturing <br />facility nearest you. (See back cover for information.) <br />Site Location: <br />Address: <br />Phone: <br />Contact Name: <br />Test Date: <br />95% - 5% TEST <br />I a. Start level (inches in standpipe) <br />2a. End level after 4 hours <br />3. Difference (subtract 2a from 1 a) _ <br />4. Calibration factor x .20 <br />5. Volume change = <br />6. Test hours - 4 <br />7. Gallons -per -hour loss = <br />(If 0.05 gallons/hour or less, tank passed.) <br />Note: maximum allowable dispensing volume during test: <br />8 -foot -diameter tank -1,200 gallons maximum <br />6 -foot -diameter tank - 500 gallons maximum <br />4 -foot -diameter tank - 300 gallons maximum <br />1 •• " <br />95% - 5% TEST <br />1 a. start level (inches in standpipe) <br />2a. End level after 6 hours <br />3. Difference (subtract 2a from 1 a) _ <br />4. Calibration factor x .30 <br />5. Volume change = <br />6. Test hours - 6 <br />7. Gallons -per -hour loss = <br />(If 0.05 gallons/hour or less, tank passed.) <br />Note: Maximum allowable dispensing volume during test: <br />10 -foot -diameter tank -750 gallons maximum <br />Tank Information: <br />Nominal Gallons: <br />Diameter: <br />Approximate Standpipe Length: <br />Product Type: <br />Person Performing Test: <br />99% -1 % TEST <br />1 b. Start level (inches in standpipe) _ <br />2b. End level after 10 hours _ <br />3. Difference (subtract 2b from 1 b) <br />4. Calibration factor x .20 <br />5. Volume change = _ <br />6. Test hours _ 10 <br />7. Gallons -per -hour loss = <br />(if 0.05 gallons/hour or less, tank passed.) <br />Note: No product dispensing allowed. <br />POUBLE-WALL TANKS <br />99% - 1 % TEST <br />tb. Start level (inches in standpipe) _ <br />2b. End level after 10 hours _ <br />3. Difference (subtract 2b from 1 b) <br />4. Calibration factor x .30 <br />5. Volume change = _ <br />6. Test hours - 10 <br />7. Gallons -per -hour loss = <br />(If 0.05 gallons/hour or less, tank passed.) <br />Note: No product dispensing allowed. <br />pei.org 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.