Laserfiche WebLink
Time In: <br /> Time Out: <br /> San Joaquin County <br /> Environmental Health Department <br /> J. 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> ... P Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sigov.orq/ehd <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: SAFEWAY FUEL CENTER 2707 Date: 04/01/2019 <br /> Address: 6425 N PACIFIC AVE, STOCKTON 95207 <br /> Requestor: CASE GILSON, ARMER/NORMAN AND ASSOCIATES INC Telephone: (925)499-1032 <br /> Program Element: 2308-UST RETROFIT Request#: SR0079901 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Mauricio Miranda ICC Service Tech/Installer Exp. Date: 01/06/2020 <br /> Manufacturer training: INCON, 08/28/20 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site to conduct a service request inspection of a 24 hour hydrostatic test equivalent using the INCON system. UDC 1/2, 3/4, <br /> 5/6, 9/10 and 11/12 after concrete installation was tested for 15 minutes at 0.002 inches leak threshold. All test passed. <br /> A 60 minute at 5 psi secondary containment was conducted on Diesel product#1, 87 product#1,87 product#2 and 91 <br /> product#1.All test passed. <br /> Verification of communication of secondary piping into all UDCS and sumps was observed to be done as required for detection <br /> of a leak at the earliest opportunity. The service technician on site removed jumper hoses and placed the sharder valves in a <br /> downwards position to meet this requirement.Be aware that secondary containment testing for the 91 product vent, Diesel <br /> product vent, 87 product vent, Diesel product#1, Diesel product#2, 87 product#1, 87 product#2, 91 product#1, 91 product <br /> #2, 87 product STP, 91 product STP, Diesel product STP, 87 product fill, 91 product fill, Diesel product fill, UDC 1/2, 3/4, 5/6, <br /> 7/8, 9/10, 11/12, 13/14, and 15/16 sump is required six months after the the installation of the penetration fittings. The <br /> secondary containment retest is due by September 2019. Provide 48 hour notification to EHD prior to conducting the testing. <br /> The facility may receive fuel at this time and may operate the 87 product, 91 product and Diesel product UST systems. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Case Gilson, Project Manager <br /> EH Specialist: ZUNA BARKER Phone: (209)953-7311 <br /> FA0002409 SR0079901 SC298 04/01/2019 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />