My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:08:50 AM
Creation date
3/20/2019 2:14:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON VALERO
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjaov.orcI/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> THORNTON 76 8606 THORNTON RD STOCKTON March 25 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> Fuel drips were observed on horizontal piping in dispenser 3/4 and dark staining was observed on the conversion frame <br /> beneath the piping, indicating a leak in the primary piping. All primary containment for the UST system must be tight. <br /> Immediately have a properly licensed, trained, and certified contractor repair or replace the failed component under <br /> permit and inspection of the EHD. <br /> This is a minor violation. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The 89 direct-bury spill container failed when tested. All spill containers shall have a minimum capacity of five gallons <br /> and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue deposition of <br /> petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and certified <br /> contractor under permit and inspection of the EHD. If the spill container can't be replaced immediately, there is a <br /> possibility that the 89 UST system may be red tagged to prevent fuel inputs. <br /> *The 89 tank contained 3,544 gallons at the time of inspection. <br /> The 87 and 91 spill containers failed to have a minimum capacity of five gallons. All spill containers shall have a <br /> minimum capacity of five gallons. Immediately contact a properly licensed, trained, and certified contractor to repair or <br /> replace the spill containers under permit and inspection of the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> The monitoring system certification is being conducted today (3/25/19) and will not be witnessed by EHD. <br /> Looked inside all sumps and UDCs. Verified sensor locations and piping communication. <br /> The routine paperwork inspection needs to be conducted and has been scheduled for4/1/19 at 10:30 AM. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: March 25, 2019 Inspector: Inspector Phone: <br /> Printed Name and Title: STACY RIVERA, Senior REHS (209)468-3440 <br /> ricky gaba, manager <br /> FA0002590 PR0232261 SCO01 03/25/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 Of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.