My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:08:50 AM
Creation date
3/20/2019 2:14:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON VALERO
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy of this form <br /> must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the <br /> USTs within 30 days of the date of the monitoring system certification . <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10180975 3-25-2019 <br /> Business Name (Same as Facility Name or DBA — Doing Business As.) Building # <br /> Stockton 76 <br /> Business Site Address City ZIP Code <br /> 8606 Thornton Rd . Stockton 95209 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> ��� CGRS ( 916 ) 991 - 1100 <br /> SOLUTIONS DELIVERED <br /> Mailing Address <br /> 5444 Dry Creek Road ; Sacramento , Ca . 95838 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification.) <br /> Garrett Warren <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> CSLB#803616 8185019 10 -2-2019 <br /> Monitoring System Training and Certifications (List all applicable certifications.) Expiration Date <br /> B42126 Veeder- root 1 -21 -21 <br /> VMI LDT- 890 Tester/ #3822 4-30 -2020 <br /> III . RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> 0 Monitoring System Set-up 0 Alarm History Report <br /> Was any monitoring equipment replaced ? <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV ❑ M ❑ <br /> below. <br /> Was damage, debris, or liquid found inside any secondary containment systems? ❑ ❑ <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? ❑ <br /> (if "No, " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> The 87 and 91 spill bucket did not hold 5 gallons . The 89 spill bucket failed and was leaking . <br /> The threads on the nipple are damaged . <br /> APR 2 2 2019 <br /> ENVIRONMENTAL <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS rS i 61TM r. IN <br /> IT <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , title 23 , division 3 , chapter 16 , section 2638 and all information contained herein is true and accurate . Attached to <br /> this certification is information (e . g . , manufacturers ' checklists , monitoring system set-up , alarm history report, etc . ) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not applicable <br />
The URL can be used to link to this page
Your browser does not support the video tag.