My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_2001 - 2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
6100
>
2300 - Underground Storage Tank Program
>
PR0231630
>
BILLING_2001 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:42 PM
Creation date
3/21/2019 11:54:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2001 - 2006
RECORD_ID
PR0231630
PE
2361
FACILITY_ID
FA0003630
FACILITY_NAME
ARCO STATION #595*
STREET_NUMBER
6100
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08704034
CURRENT_STATUS
02
SITE_LOCATION
6100 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"FIED PROGRAM CONSOLIDATED FO" <br /> 1 TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> - (two pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ® 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: I <br /> ARCO FACILITY#00595 STOCKTON <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes S No 434 <br /> 2-UNL XERXES If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 12-1-1984 12,000 ONE <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 431) PETROLEUM TYPE 440 <br /> ® 1. MOTOR VEHICLE FUEL ®I a. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) ❑I b. PREMIUM UNLEADED [13. DIESEL ❑6. AVIATION FUEL <br /> [12. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 44' <br /> ❑4. HAZARDOUS WASTE GASOLINE 8006-61-9 <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH [15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC [15. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank [11. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 44� <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ® 1 SPILL CONTAINMENT 2004 ® 1 ALARM 2004 ®3 FILL TUBE SHUT OFF VALVE 2005 <br /> ®2 DROP TUBE 2004 ®2 BALL FLOAT 2004 ❑4 EXEMPT <br /> ®3 STRIKER PLATE <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 4'4 <br /> (Check one item only) <br /> ❑I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> 0 gallons ❑Yes ❑ No <br /> UPCF(1/99 revised) 173 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.