ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987 - 2006
RECORD_ID
PR0231630
PE
2361
FACILITY_ID
FA0003630
FACILITY_NAME
ARCO STATION #595*
STREET_NUMBER
6100
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08704034
CURRENT_STATUS
02
SITE_LOCATION
6100 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUNTER ENVIRONMENTAL SERVICES, INC. FINAL TEST RESULTS <br /> 18350 MT. LANGLEY STREET, SUITE 101 TEST DATE: 03/01/88 <br /> FOUNTAIN VALLEY, CA 92706 <br /> 800-247-9014 800-247-2186 <br /> CUSTOMER: ARCO LOCATION/IDENTIFICATION NO.: 00595 <br /> ADDRESS: 6100 N. Highway 99 <br /> Stockton, CA <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PUMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> NO. PRODUCT RUCTE S= APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br /> 1 Super 12000 92/FG 0 157 +.014 Tight <br /> 2 U/L 12000 92/FG 0 149 +.014 Tight <br /> 3 Reg 12000 92/FG 0 160 -.015 Tight <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PIMP POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> NO. PRODUCT REMOIE S APPLIED HELD HELD LOSS CC's LOSS GPH /RESULT <br /> 1 Super Red Jacket 50 48 15 Tight <br /> 2 U/L Red Jacket 50 46 15 Tight <br /> 3 Reg Red Jacket 50 49 15 Tight <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> TEST TIME LEAK RATE TEMPERATURE ABSOLUTE CHECK <br /> SYSTEM TEST LEVEL CLUX WMTIUN COMPENSATION LEAK RATE TEST <br /> NO. PRODUCT NO. (IN.) STATE (HR-MIIN) CC/DIV CC/MIN DELTA of CC/MIN CC/MIN GPH Y/N <br /> 1 Super 1 157 12:15 0-30 4.054 +5.993 +.010 +5.079 +.914 +.014 <br /> 2 U/L 1 149 10:40 0-44 3.692 +2.387 +.003 +1.512 +,875 +.014 <br /> 3 Reg 1 160 11:30 0-35 6.383 -1.473 -.001 -.502 -.971 -.015 <br /> *LEVEL - Inches frcm Tank Bottom to Test Level <br /> ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br /> CERTIFICATION <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOCATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br /> established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br /> Tests Conducted and Certified By: Test Van No. 19 <br /> Team Manager: Roger Renko <br /> Tank Testing Specialist: Chris Dorazio <br />