REVISIONS <br /> REFRIGERATION LEGEND <br /> SYMBOL DESCRIPTION <br /> oR REFRIGERATION CASE CONNECTION <br /> ARCH.PROJECT NO. <br /> 2011 <br /> DRAWN <br /> JR <br /> CHECKED <br /> MC <br /> SUBMITTAL DATES <br /> OTB DATE <br /> 11/24/2020 <br /> W cCFF��a LL <br /> cSaw Va00 a <br /> ¢oa OW�i po <br /> OVd0.V <br /> 4�, o <br /> doz��wFy (J c x <br /> a 0 O Z o oN <br /> 7 8 9 <br /> V <br /> a ��y�+o �o F <br /> GENERAL NOTES Os a <br /> q�''�a�6WQU W O <br /> ��CZCZ c�iNc7��66,„333.F Le 4ALJ c '� a_ <br /> WW q q 8 <br /> qz K m a O�� T c N <br /> y q � u ' <br /> _^^ <br /> 1. PIPING SHALL BE LOCATED SO THAT ACCESS TO THE SYSTEM A z W 3 N <br /> COMPONENTS IS NOT HINDERED AND THAT ALL COMPONENTS THAT <br /> COULD REQUIRE FUTURE MAINTENANCE ARE EASILY ACCESSIBLE. <br /> 2. THE REFRIGERATION CONTRACTOR SHALL REVIEW AND STRATEGICALLY <br /> Fff <br /> �, LOCATE ALL CONTROL VALVES PRIOR TO THE INSTALLATION OF ANY <br /> PIPING. <br /> 3. THE REFRIGERATION CASE MANUFACTURER SHALL FURNISH AND <br /> INSTALL ONE ISOLATION LIQUID LINE HAND VALVE IN EACH REMOTELY <br /> REFRIGERATED CASE FOR CLEANING AND MAINTENANCE PURPOSES. <br /> 4. DRAWING IS SHOWN PARTIALLY DIAGRAMATICALLY FOR CLARITY a� • <br /> PURPOSES ONLY. EACH REFRIGERATION LINE DISPLAYED ACTUALLY <br /> REPRESENTS A LIQUID AND SUCTION LINE PER PAIR CIRCUIT. e <br /> 5. THE REFRIGERATION CONTRACTOR SHALL COORDINATE ALL PIPING e <br /> PATHS TO AVOID CONFLICTS WITH ELECTRICAL PANELS, HALLWAYS. b,hills architecture, PC <br /> ABSOLUTELY NO PIPING SHALL PASS ABOVE ELECTRICAL PANELS AND 3156 south b o w n w a y <br /> -- TRANSFORMERS OR THROUGH HALLWAYS. b o i s e d a h o 83706 <br /> 1 6. THE REFRIGERATION CONTRACTOR SHALL COORDINATE ALL PIPING P 2 0 8 . 2 5 8 6 1 5 0 <br /> PATHS TO AVOID CONFLICTS WITH ALL OTHER TRADES. (I.E. HVAC <br /> EQUIPMENT, HVAC DIFFUSERS, DUCT WORK, FLUES, LIGHT FIXTURES, www b h i l l s a r c h . c o m <br /> - PLUMBING LINES, DECOR, PALLET RACKING, ETC.) <br /> 7. THE REFRIGERANT CONTRACTOR SHALL INVESTIGATE AND ENSURE <br /> I COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL CODES PRIOR TO <br /> OFESS/ <br /> G - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ _ _ _ G INSTALLATIONS. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE p R 41/4 <br /> - WITH ALL APPLICABLE CODES. <br /> I <br /> 8. MOUNT OVERHEAD REFRIGERATION LINES EITHER INSIDE OR WITHIN 3" m • <br /> (R) (R) (N) OF BOTTOM OF BAR JOIST. ALWAYS MAINTAIN PROPER SLOPE BACK TO 885 <br /> O O A9 THE COMPRESSOR RACK, IF NECESSARY INSTALL INTERMEDIATE RISERS * XP: 12/31/21 <br /> R TO MAINTAIN ELEVATION. crj ��CP <br /> 9. SUCTION P-TRAPS TO BE SAME SIZE AS HORIZONTAL RUNS, REDUCE WITH 9TFnc CA <br /> BUSHINGS AT THE TOP SIDE OF P-TRAP. INTERMEDIATE P-TRAP SIZE <br /> SHOULD BE THE SAME SIZE AS REDUCED RISER. 11/18/2020 <br /> 10. TO FACILITATE MOVEMENT OF THE PIPING AS A RESULT OF <br /> CONTRACTION AND EXPANSION DURING REFRIGERATION OPERATION �..� <br /> THE REFRIGERATION CONTRACTOR SHALL INSTALL EXPANSION LOOPS M <br /> THROUGHOUT THE STORE'S REFRIGERATION PIPING IN FULL COMPLIANCE O <br /> WITH THE ASHRAE STANDARDS AND LOCAL CODES AND REGULATION. <br /> PIPE HANGARS SUPPLIED AND INSTALLED BY THE REFRIGERATION <br /> CONTRACTOR MUST PERMIT FREE MOVEMENT OF THE REFRIGERANT Q� <br /> LINES. <br /> 11. INDIVIDUAL REFRIGERATION BRANCH SIZES ARE SHOWN ON THE J <br /> REFRIGERATION SCHEDULE. <br /> 12. CASE TEMPERATURE PROBES SUPPLIED AND INSTALLED BY CASE <br /> MANUFACTURER. �J•� <br /> 13. REFRIGERATION CONTRACTOR TO WIRE AND TERMINATE ALL LOW <br /> VOLTAGE DEVICES. BELDEN 8762 OR EQUIVALENT. THIS WIRING SHOULD I�—I <br /> BE CAREFULLY ROUTED AWAY FROM POWER LINES OR OTHER HIGH O 0 <br /> ELECTRICAL NOISE ENVIRONMENTS. <br /> 14. AFTER LINES ARE INSTALLED REFRIGERATION CONTRACTOR TO FILL I--I <br /> OPENINGS IN CASES WITH EXPANDING FOAM INSULATION. <br /> 15. UPON COMPLETION OF INSTALLATION, REFRIGERATION CONTRACTOR TO O .� <br /> (N) ENSURE ALTERED PROTOCOL UNITS ARE PROPERLY CHARGED WITH <br /> REFRIGERANT. <br /> 3 16. COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS O <br /> REGARDING REFRIGERANT RECLAIMING, SYSTEM EVACUATION, <br /> EQUIPMENT, OIL AND REFRIGERANT DISPOSAL. <br /> 17. COMPLETE APPROPRIATE WINCO FOODS REFRIGERANT TRACKING FORMS 0C <br /> AND PROVIDE DOCUMENTATION THAT ALL OTHER REGULATIONS HAVE <br /> N <br /> BEEN COMPLIED WITH. <br /> KEYED NOTES <br /> 1. CONNECT NEW CASE AND NEW PIPING TO EXISTING STUB AT - <br /> 7 g 9 RACK. CONTRACTOR TO SUPPLY AND INSTALL NEW CONTROL <br /> VALVE AT RACK. RE: R4. SEE R5 FOR CPC CONTROL IO POINTS. <br /> 2. RELOCATED CASE. RE: ARCH PLANS. <br /> PARTIAL REFRIGERATION PIPING PLAN ORT 3. NEW SELF CONTAINED CASE. RE: ARCH PLANS. <br /> �1 — <br /> 1/4 - 1 -011 <br /> bm <br /> SHEET TITLE <br /> PARTIAL <br /> REFRIGERATION <br /> w PIPING PLAN <br /> SHEET <br /> R2O <br /> N <br /> O <br /> N <br /> 00 <br /> ,--i <br />