Laserfiche WebLink
i <br /> REvrslors <br /> KEYED NOTES <br /> 8 GENERAL NOTES <br /> 10 9 <br /> 1. THIS PLAN SHOWS GENERAL DEMOLITION WORK TO BE PERFORMED 1. REMOVE PORTION OF EXISTING CEILING ONLY AS REQUIRED AND TO No. Description Date <br /> L <br /> - AND DOES NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION ACCOMMODATE NEW CONSTRUCTION,RE: A8 <br /> i Ir - I 11 Ifi <br /> �� ° � - € T_- <br /> WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN RE: A8 FOR NEW CONSTRUCTION. <br /> - - ON THE REMAINING CONTRACT DOCUMENTS. THE CONTRACTOR SHALL 2. REMOVE EXISTING FURRED WALL&ALL RELATED ITEMS TO ACCOMMODATE <br /> 1 - ._.W <br /> COORDINATE AND VERIFY THE ENTIRE DEMOLITION SCOPE WITH THE NEW CONSTRUCTION,RE:A2. <br /> ARCHITECT OF RECORD AND WINCO CONSTRUCTION MANAGER. 3. REMOVE EXISTING PALLET RACKS WHERE SHOWN. FILL HOLES IN EXISTING <br /> 2. FOR DEMOLITION WORK AS A RESULT OF EXISTING EQUIPMENT AND CONCRETE AS REQUIRED,RE: SPEC. SECTION 033000,TYP. <br /> FIXTURE REMOVAL REFER TO PLUMBING, HVAC,ELECTRICAL,AND 4. REMOVE EXISTING CASE CORNER GUARDS AND/OR CART STOP WHERE <br /> REFRIGERATION DRAWINGS FOR REMOVAL,OF REQUIRED SYSTEMS. SHOWN. FILL HOLES IN EXISTING CONCRETE AS REQUIRED,RE: SPEC. <br /> -- 3. EQUIPMENT ITEMS TO-BE REMOVED ON THIS PLAN OR THE REMAINING SECTION 033000,TYP. 1802 o�crrra. <br /> DRAWN <br /> R <br /> CONTRACT DOCUMENTS SHALL REMAIN THE PROPERTY OF WINCO. S. REMOVE EXISTING PRODUCE RACKS TO ACCOMMODATE NEW RACKS 8r � , <br /> NEW REFRIG.MOBILE PRODUCE ENDS, RE:FP2. <br /> THE CONTRACTOR SHALL PLACE THE EQUIPMENT IN STORAGE OR <br /> DISPOSE OF AS DIRECTED BY WINCO. (WASTE MATERIALS SHALL BE 6. REMOVE EXISTING CASES&ALL RELATED ITEMS,TYP. TO INCLUDE C' C' ' <br /> D.C./CR <br /> DISPOSED OF IN AN APPROVED MANNER) FOR PERSPECTIVE WINCO REMOVAL OF ALL EXISTING FLOOR SINKS [,a7 CASES. CAP&ABANDON SUBUMALDA'MS <br /> SALVAGE ITEMS,REFER TO MECHANICAL,ELECTRICAL AND HVAC EXISTING PLUMBING LINES BELOW SLAB IF NOT REUSED FOR NEW <br /> _= DRAWINGS. CASES,RE: GN#2. <br /> 4. CONTRACTOR SALVAGE ITEMS SHALL BE DISPOSED OF PROPERLY OFF 7. EXISTING STUD WALL TO REMAIN.REMOVE INSIDE FINISHES DOWN TO nx�n�x <br /> - PREP. FOR NEW FINISHES. <br /> I - ---- - SITE AND IN A EXPEDITIOUS MANNER. STUD& <br /> 5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK,USING 8. REMOVE ALL EXISTING PLUMBING FIXTURES &TERMINATE ALL <br /> L THE CONTRACTOR'S BEST SKILL AND ATTENTION. THE CONTRACTOR RELATED PLUMBING LINES,RE: PI &P2 FOR COORDINATION. <br /> SHALL BE RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION 9. REMOVE EXISTING TILE FLOORING AND CONC. SLAB,RE:A1,A9,PO&P . <br /> / . <br /> 10. REMOVE EXISTING PRODUCE CASE ANGLES FILL HOLES IN EXISTING CONCRETEzilIg n <br /> MEANS METHODS TECHNIQUES, SEQUENCES,(UNLESS A SEQUENCE IS <br /> SPECIFIED BY THE OWNER OR CONTRACT DOCUMENTS) AS REQUIRED,RE: SPED. SECTION 033004, TYP. U S 9 a 9 � <br /> 6 _ STRUCTURES AND/OR 11. REMOVE EXISTING GRAB BARS. <br /> 6. SHORING OF STRUCTURAL FOUNDATION, � � <br /> -- Z REQUIRED TO COMPLETE THE WORK DESCRIBED IN THE 12. REMOVE EXISTING SOAP DISPENSER. <br /> I l I TRENCHING <br /> - CONSTRUCTION DOCUMENTS IS CONSIDERED A METHOD OR TECHNIQUE 14. REMOVE EXISTING DIAPER CHANGING STATION. o <br /> - =- - - - . - RY 15. REMOVE EXISTING SANITARY NAPKIN DISPOSAL. <br /> F I _- -_ AND IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IF A REGULATO DISPENSER. <br /> o <br /> - 27 �__�LW _ L AGENCY REQUIRES A LICENSED ARCHITECT OR ENGINEER TO SUPERVISE 16. REMOVE EXISTING TOILET TISSUE DISP g <br /> i 25 Q R SHORING OF STRUCTURAL. 17. REMOVE EXISTING TOILET SEAT COVER DISPENSER. ' a <br /> � y wti AND/OR APPROVE DRAWINGS FOR <br /> 28 FOUNDATIONS, STRUCTURES AND/OR TRENCHING IT IS THE 19. REMOVE EXISTING MIRROR. fl <br /> ' - - -- RESPONSIBILITY OF THE CONTRACTOR TO CONTRACT WITH THE 20. REMOVE EXISTING HAND DRYER. <br /> ARCHITECT/ENGINEER. THE CONTRACTOR WILL PROVIDE THIS WORK. 21. REMOVE EXISTING RESTROOM PARTITIONS. <br /> 22. REMOVE EXISTING COAT HOOKS. <br /> AS PART OF THE BASE BID. <br /> 7. DIMENSIONS SHOWN ON PLAN ARE FOR GENERAL REFERENCE BIDDING 23. REMOVE EXISTING COUNTER. <br /> PURPOSES ONLY. DIMENSIONS.ARE NOT EXACT AND ARE SHOWN ONLY 24. REMOVE EXISTING CORNER GUARD. <br /> TO PROVIDE A GENERAL IDEA OF EXTENT OF DEMOLITION REQUIRED. 25. REMOVE EXISTING WEDGE CABINET. <br /> ! I 1 8. PROTECT ALL EXISTING ITEMS THAT AUTO REMAIN FROM DAMAGE 26. REMOVE ALL EXISTING SIGNAGE. .., <br /> -I DURING DEMOLITION AND CONSTRUCTION. 27. EXISTING FIXTURES AND EQUIPMENT TO BE TEMPORARILY RELOCATED U N <br /> ! AND OPERATIONAL FOR USE DURING CONSTRUCTION.PROVIDE MINIMUM H <br /> I <br /> E F DEMOLITION WHERE REQUIRED FOR TEMPORARY HOOK-UPS- PREPARE ALL ;� w <br /> I <br /> DEMOLISHED AREAS FOR PATCH BACK TO MATCH EXISTING ADJACENT W <br /> I I ! <br /> SURFACES. <br /> 28. PREPARE AREA AND PROVIDE PLUMBING AND ELECTRICAL SERVICES w <br /> REQUIRED TO RECEIVE TEMPORARILY RELOCATED FIXTURES AND EQUIPMENT W <br /> AS INDICATED. * d <br /> 29. REMOVE PORTION OF EXISTING FURRED WALL TO 5" ABOVE NEW CASE ,RE:FP3 24. 0 dL 8� <br /> E <br /> 2;1 <br /> �- <br /> 29 6 1 7 24 1 I! 7 24 7 24 7 1 1 24 7 i <br /> I' 23 I i � I I ! I ®F GAS-lir <br /> � � I I I 26 -- _ 26 <br /> 22 22 r <br /> 5 I ..�, <br /> to <br /> 24 I 23 ( I I _ 12 24 <br /> D f Ii 20 7 12 f I I ll L_ 20 <br /> 19 <br /> 8 1�111 =-� <br /> 8 Q <br /> 10 <br /> I - 19 12 1 6 19 ! Q <br /> H � <br /> 1 1 i7 I �+ <br /> W Z � <br /> 21 I U v o E� <br /> � U <br /> I �1 - - - <br /> 5 - _ = Q ►- <br /> 1= - 1� - - o ao <br /> 101 I - 1 16 8 I I i � N <br /> 14 I 8 21 U <br /> � _ . <br /> II <br /> 1617 $ <br /> 8 i I 17 i <br /> 15 <br /> ��. 16 <br /> - � I I � 21 �F� - � - - - -- - - I 1 17 <br /> 3 1 I I I �` 16 8 17 I <br /> 15 16 21 <br /> I 7 1 7 1 14 <br /> 14 I ! I <br /> I - � -. _ - _I 17 I I 17 <br /> 2 8 I ! 8 2 I 1 !I <br /> I I I I 7 11 16 I D <br /> 11 7 <br /> - _ - - I I - - -II <br /> ---- I I I I I <br /> 0 <br /> SHEET TITLE <br /> 2 DEMOLITION PLANS <br /> NpR�, NpR��T <br /> ENLARGED PARTIAL DEMOLITION PLAN - RESTROOMS <br /> ENLARGED PAI PIAL DEMOLITION PLAN - PRODUCE � SHEET <br /> 318" = 1'-0" <br /> 3132"= 1'-0" <br />