My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999 - 2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
6100
>
2300 - Underground Storage Tank Program
>
PR0231630
>
COMPLIANCE INFO_1999 - 2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:12 PM
Creation date
3/21/2019 1:29:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999 - 2000
RECORD_ID
PR0231630
PE
2361
FACILITY_ID
FA0003630
FACILITY_NAME
ARCO STATION #595*
STREET_NUMBER
6100
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08704034
CURRENT_STATUS
02
SITE_LOCATION
6100 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
( h ) Underground storage tank quantity measurements shall be based on liquid level measurements <br /> which are: <br /> ( 1 ) Performed during periods when no additions or withdrawals are being made to the <br /> underground storage tank; <br /> ( 2 ) Performed by the underground storage tank owner, operator, or other designated <br /> persons who have had appropriate training; <br /> ( 3 ) Based on the average of two readings if stick or tape measurements are used: <br /> ( 4 ) Determined by equipment capable of measuring the level of the product over the full <br /> range of the tank's height to the nearest one-eighth of a inch; <br /> ( 5 ) Determined by equipment capable of measuring, to the nearest one-eighth of an inch, <br /> water present in the bottom of the underground storage tank. If the underground <br /> storage tank is not level, and the measurements are taken manually, then the <br /> measurement should occur at the lowest end of the underground storage tank; <br /> ( 6 ) Measured at the center of the longitudinal axis of the underground storage tank if access <br /> is available or measured at the lowest end of the underground storage tank with a <br /> calibration measurement at both ends, if possible, to determine if any underground <br /> storage tank tilt exists and, if so, its magnitude; and <br /> ( 7 ) Converted to volume measurements based on a calibration chart for the underground <br /> storage tank. This chart shall, where feasible, take into account the actual tilt of the <br /> underground storage tank. <br /> ( i ) The daily variation in inventory reconciliation shall be the difference between physically <br /> measured inventory in storage and the calculated inventory in storage. The physically <br /> measured inventory shall be determined at approximately the same time each day by taking <br /> liquid level measurement and converting it to gallons using the calibration chart. The <br /> calculated inventory shall be determined at approximately the same time of day for each <br /> business day by adding the inputs and subtracting the withdrawals from the physically <br /> measured inventory determined the day before. These variations shall be summed for a period <br /> of one month. Monthly variations exceeding a variation of 1.0 percent of the monthly tank <br /> delivery plus 130 gallons must be investigated in accordance with this section. <br /> ( j ) The owner or operator shall, on an annual basis, submit a statement to the local agency which <br /> states that all inventory reconciliation data are within allowable variations or which includes <br /> a list of the period of times and the corresponding variations which exceed the allowable <br /> variations. Said statement shall be executed under penalty of perjury. <br /> ( k ) If the monthly inventory reconciliation, conducted under subsection (i) of this section, <br /> exceeds the allowable variation, the owner or operator as appropriate shall: <br /> ( 1 ) Notify the local agency of a suspected unauthorized release within 24 hours of <br /> completing any inventory reconciliation which exceeds the allowable variation; <br /> ( 2 ) Within 24 hours of discovering a variation which exceeds the allowable variation, <br /> review the inventory records for the preceding 30 days and determine if a calculation <br /> error exists that caused the apparent excessive variation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.