LPROJECT
<br /> Interior Tenant Improvement for:
<br /> IF
<br /> aim
<br /> CONTROL AND OPERATING MEGHAN151YI5:
<br /> THE CONTROLS AND OPERATING MECHAN15M5 SHALL BE OPERABLE WITH ONE 15124 Harlan Road
<br /> HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF Suite #C-�
<br /> THE WRIST. THE FORGE TO ACTIVATE THE CONTROLS SHALL BE NO GREATER
<br /> THAN 5 POUNDS OF FORGE, GBG W,513.8, ITEM #4. Lathrop, CA 95330
<br /> ELECTRICAL SCHEDULE
<br /> i
<br /> ROUGH-INS SERVICE TO AIR CURTAIN WITH DOORl
<br /> 2q 28
<br /> ACTIVATED 5WITGH.
<br /> 5" DESCRIPTION MOLT/PH AMP H.P. HGT LOCATION ITEM DE50RI1F"TI0N REMARKS --- - - I'-10"
<br /> I Dad. Outlet 115/1 2.5 - +24" Bar Die P.0.5. 5y5tem Unit provided with cord 4 plug. - - -
<br /> 2 Ded. Outlet 115/1 2.5 - +24" Bar Die P.0.5, System Unit provided with cord 4 plug.
<br /> 11 - O
<br /> 3 Ded. Outlet 115/1 2.5 - +24" Bar ::)[e P.O.S. System Unit provided with cord plug. / L I +48"
<br /> 4 Outlet 115/1 8.0 -- +i5" Wall - Pizza Warmer Unit Provided wlGord & Plug
<br /> 5 J-Box If5/1 7.0 I/4 +15" Noll - Refrig. Salad Pan Insert Run 5eol Tight Flex Conduit }
<br /> l
<br /> b J-Box 15/1 2:0 +15" Wail Display Lighting (Salad) Run Seal Tight Flex Gondult
<br /> (E)E P"A" PROJ
<br /> 7 outlet 115/1 5.0 - +60" Wah - 50da Dispenser Unit provided with cord 4 plug. ECT TEAM
<br /> 8 J-Box 208/1 1.5 - +72" Hall/Roof - Ice Machine/Cordensor (Roof) Run Seal Tight Flex Conduit o J 27 GENERAL CONTRACTOR:
<br /> q Dad, Outlet I5/I 2.5 - +48" Noll - P.C.5. Stem Unit rovided with cord plug, i Allan Daniel
<br /> p p g' N Allan Daniel Construction
<br /> 10 6 Outlets 115/1 5.0 - +15" Wall - Hot Bag System Unit provided with cord 4 plug./Coordinate w/K.E.G: T 3310 6lenside Drive Laffette, GA 945411
<br /> !I J-Box 115/1 12.0 - +120" Hall - Beer Pumping System Run Seal Tight Flex Conduit p (425) 260-3354.,(425) 284-8704 Fax.
<br /> n o N adanielconstaromcast.net
<br /> 12 J-Box 115/1 15.0 - +126" WQII/ROof - W.I. Gooier Comp./Gond. Run Seal Tight Flex Conduit 26 KITCHEN EQUIPMENT CONTRACTOR:
<br /> 13 J-Box 115/I 5,0 - +126" Wa11 - W.I. Cooler Lights/switch Run Seal Tight Flex Conduit Pizza Oven Professionals
<br /> 14 Outlet 115/1 12.0 -- +15" Wall -- (2)Door Refrig. Bockbar Unit Provided P4/cord $ Plug Tm Costello
<br /> (q07) "133-1413., (407) 733-1414 Fax.
<br /> 15 J-Box II5/1 5.0 - --> Header - Heat Lamp Run Seal Tight Flex Conduit ovenman®mtaonEine.net
<br /> 16 Outlet II5/1 6.5 - +15" Hok - U/C Refrigerator Unit provided wlth cord 4 plug
<br /> 17 J-sox 115/1 5.0 -- +108" Wall - Hood Lighting Run Seal Tight Flex Conduit
<br /> 15 J-Box 115/1 120 - +36/54" Wall - Pizza Ovens Run Seal Tight Flex Conduit
<br /> 14 J-Box 115/1 - 1.0 Roof - Exhaust Blower Run Seal Tlght Flex Gondult
<br /> 20 J-Box II5/1 - .75 --> Roof - Make-Up Air Unit Run Seal Tight Flex Conduit
<br /> 21 J-Box 115/1 2.5 - --> Above Glg. - Fire Suppression System Run Seal Tight Flex Conduit
<br /> 22 Outlet II5/I 14.0 - +15" Wall - Refrig. Pizza Make-Up Table Unit Provided with Cord s Plug to
<br /> 23 Outlet II5/I 14.0 - +15" Noll - Refrig. Pizza Make-Up Table Unit Provided with Cord 4 Plug +72" ® r
<br /> 24 Outlet 115/1 1.0 -- +I5" Half - (I)Door W.T. Refrigerator Unit Provided vi/cord s Plug
<br /> + r\7
<br /> 25 Outlet 13/1 12.0 -- +7b Wa1I - (I)Door Freezer Unit Provided w/Cord B Plug +72" i' .. II
<br /> 26 Outlet 115/1 12.0 -- +`12" M Wall - Dishwasher Unit Provided w/Gord 4 Plug -- ----L -
<br /> 25
<br /> -------------L I
<br /> 27 J-Box 208/3 - 2.0 +15" Wall - Mlxer Run Seal Tight Flex Gondult
<br /> '`� DESIGN TEAM
<br /> 28 Outlet I5/I b.0 3/4 +48" Wall - Dough Roller Unit provided with cord plug, - 1 I � 24
<br /> 21 J-Box il5/i 4.0 - +qb' Noll - Air-Curtain Run Seal Tight Flex Gondult I I I I 72
<br /> 30 m ; i ,�' `' ; ; Roy Anderson, P.E.
<br /> 31 f F, I I +72
<br /> 32
<br /> NOTE: ELECTRICAL CONTRACTOR TO VERIFY ELEGTRIGAL REQUIREMENT5, LOADS ETC. OF OWNER SUPPLIED EQUIPMENT PRIOR TO CONSTRUCTION. i 'ti ON ROOF
<br /> ALL OUTLETS 5HOWN WITHOUT ITEM NUMBER5 TO BE 15/1 GONV. OUTLET a +15" A.F.F., U.N.O. + + , I I +1:21 2337 Wyatt COun
<br /> Santa Rosa, CA 95403
<br /> (707) 322-8403/ royanderson706@gmaii.com
<br /> 111 I I I
<br /> RANT DESIGN
<br /> ELECTRICAL NOTES ELECTRICAL SYMBOLS 111 I I 1 +72"
<br /> 1I
<br /> 1. E.C, TO PROVIDE 115V, IPH "ROOF MOUNTED" G.F,I.G.(W.P.) SERVICE OUTLET(5) DUPLEX OUTLET --- ----------J
<br /> WITHIN 25'0" OF ALL ROOF MOUNTED EQUIPMENT PER GODS. II J -- +72' VirTek Design
<br /> 2. E.G. TO COORDINATE W/K.E.G./W.I. BOX MFGR, ON ALL ELEGTRfGAL BOXES DUPLEX OUTLET W/ISOLATED CND./PHONE ---❑ 0 q V.I.F. 4505 Pacific Street
<br /> TO BE PLACED IN COOLER WALLS. ALL ELECTRICAL CONDUIT/PENETRATIONS O JUNCTION BOX � 21 Q � _ _ _ � 22 =.. Farmington,NM 87401
<br /> TD BE SEALED PER D.E.H. REQUIREMENTS. I''7" I'-4" (707)291-1512
<br /> " - r--- i 1 Email:projectdesign2415@gmail.com
<br /> 3. E.G. TO PROVIDE (b} D.G.O.S (FROM 2-20A CIRCUITS} FOR HOT BAC DELIVERY �'" `\b CONNECTION TO FIXTUREWIRED BY E.G. +48 r
<br /> 5Y5TEM, COORDINATE REQ'S WITH K.E.G./DWNER PRIOR TO CONSTRUCTION, �- r -�
<br /> 4. ALL ELECTRICAL OUTLETS AND CONNECTIONS 5HOWN ON TH15 PLAN ® 5WITGH I SH EJAIJU&
<br /> ARE FOR FOOD SERVICE FIX7URE5 AND EQUIPMENT 5HOWN ON FOOD
<br /> 5ERV€GE EQUIPMENT FLOOR PLAN ONLY. ( SEE ARCHITECTS PLAN FOR $ P 5WITGH, WITH PILOTT I LIGHT i �� �~\� Iq 20 ELECTRICAL EQUIP. ROUGH-INS
<br /> FURTHER BUILDING ELECTRICAL REQUIREMENTS ) 8 7 � III
<br /> 5. ALL HORIZONTAL DIMENSIONS ARE GIVEN FROM FINI5HED WALL TO VAPOR PROOF LIGHT FIXTURE +15" I �� SCHEDULES & DETAILS
<br /> (ENTER LINE OF OUTLET OR FROM CENTER LINE OF OUTLET TO CENTER
<br /> LINE OF OUTLET UNLE55 OTHERWI5E NOTED. ALL OUTLETS NOTED ( +12" ) REMOTE REFRIGERATION CONNECTION. (
<br /> ETC., TO STUB OUT OF WALL AT HEIGHT GIVEN. ALL OU7LET5 NOTED AS
<br /> 'STUB - UP' TO 'STUB - OUT' OF TOP OF FINISHED FLOOR OR FINISHED CURB, BULK CO2 LINES, VERIFY "FOR, 6 0 � � `�
<br /> A5 CASE MAY BE. A MAX. OF 4" 50 AS NOT TO INTERFERE WITH THE INSTALLATION =� $
<br /> OF FIX7URE5 AT LOCATION SHOWN. CONTRACTOR TO VERIFY ALL NOTE: RECEPTACLE OU7LET5 ARE INSTALLED AT NO r cv
<br /> DIMEN51ON5 AT J055ITE. COMPLY W/G.B.G. #I1178,6. LE55 THAN 15" A.F.F., GBG SECTION IIB.
<br /> 6. ALL CONVENIENCE OUTLETS TO BE SET HORIZONTALLY, ALL 120 VOLT I I Ib
<br /> OU7LE75 NOT DESIGNATED WITH SPECIFIC LOADS TO BE RATED AT
<br /> 15 AMPS. ALL 208 VOLT OUTLETS NOT DESIGNATED WITH SPECIFIC ELECTRICAL NOTE:
<br /> LOADS TO BE RATED AT 3/4 H.P. INSTALLATION HEIGHTS OF ELECTRICAL 5WI7GHE5 AND
<br /> 7. ELECTRICIAN TO PROVIDE MAGNETIC STARTERS AND THERMO - OVERLOAD RECEPTACLE OUTLETS REGEP7AGLE5, ELECTRICAL 5WITGHE5 L �O �1
<br /> PROTECTION ON ALL MOTORS WHERE REQUIRED. AND CONTROLS AND 5WITGHE5 INTENDED TO BE USED BY 15 J
<br /> THE OCCUPANT OF THE ROOM OR APPLIANCES, HVAC CONTROLS I IN HDR.
<br /> 8. ELECTRICIAN TO GONNEGT ALL ELECTRICAL EQUIPMENT AND SHALL BE LOCATED NO MORE THAN 48 MEASURED FROM TOP i +48"
<br /> FIXTURES AND DO ANY INTERNAL WIRING REQUIRED FIXTURES OF THE BOX OR LE55 THAN 15" MEASURED FROM THE BOTTOM
<br /> q. FIXTURE FABRICATOR WILL GUT AGGE55 HOLES TO CONVENIENCE OUTLETS OF THE OUTLET BOX TO THE LEVEL OF THE FINI5HED FLOOR.
<br /> PROVIDE NOTE TO DEM05TRATE COMPLIANCE W/G.B.G.
<br /> IN BACK SPLASHES, ETC., BUT ELECTRICAL CONTRACTOR TO PROVIDE 14
<br /> EXTENSION 5HIELD5 IF REQUIRED. 4.24
<br /> 10, ELECTRICIAN TO PROVIDE STAINLESS STEEL COVER PLATES FOR ANY
<br /> FULLY OR PARTIALLY F-XP05E=D PULL BOXES AND/OR ELEGTRIGAL AGGE55 I
<br /> BOXES AND TO PROVIDE STAINLESS 57EEL COVER PLATES FOR ALL
<br /> CONVENIENCE OUTLETS. Iii
<br /> 11. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL LOCKOUT DEVICES .\`" SCALE A5 NOTED
<br /> ON ALL BREAKERS FOR CLOCKS, REFRIGERATION, CONTROL WIRING AND ----------
<br /> FIRE EXHAUST SYSTEM CONTROLS,
<br /> 4 W, I" JOB.No. RTP-LTH
<br /> 12. E.C. TO COORDfNATE WITH 500A REP./OWNED ON SYRUP LINES FROM BAG- DRAWN BY: ON
<br /> N-BOX TO BEVERAGE DISPENSER. FLEXSLE SODA LINES PROVIDED BY 2 3 CHECKED BY:
<br /> SODA REP., E.G. TO PROVIDE CONDUIT IF REQUIRED.
<br /> 13. ALL ELECTRICAL WORK TO BE PERFORMED PER 2016 G.E.G. / STATE
<br /> PLOT DATE: 11/20/2015
<br /> GODE5, E.G TO BE AWARE OF 5AID CODES PRIOR TO GON5TRUGTION.
<br /> 14. INSTALLATION HE6HT5 OF ELECTRIGAL 5WI7GHE5, RECEPTACLES AND CONTROLS: VISIONS
<br /> CONTROLS AND 5WITGHE5 TO BE USED BY THE OGGUPANT TO THE ROOM OR AREA
<br /> y -0 CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCE OR GOOLiNG, HEATING
<br /> AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48" MEASURED
<br /> ° FROM TOP OF THE OUTLET BOX NOR LE55 THAN 15" MEASURED TO THE BOTTOM OF
<br /> L2 THE OUTLET BOX TO THE LEVEL OF THE FIN. FLOOR OR WORKING PLAT. PER G.B.G.
<br /> 15. G.E.G. 210-5: ALL 125 VOLT, SINGLE PHASE, 15 4 20 AMP REGEPTAGLES IN
<br /> O�
<br /> s E KITGHEN AREAS SHALL HAVE (FIG PROTECTION FOR PERSONNEL.