My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 11:41:32 AM
Creation date
3/22/2019 8:06:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page ;Inspec;tion <br /> FTypef Action ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Mo <br /> L FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10182131 12/ 13/2018 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Pilot Flying J 168 Ripon <br /> Business Site Address City ZIP Code <br /> 1501 N . Jack Tone Rd . Ripon 95366 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Jose Ochoa (888 ) 972 - 7581 <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 804431 8004551 - UT 12/27/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> OPW Cert # 100826 Expiration Date : 1 - 19 -2020 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method p Manufacturer Guidelines (specify): <br /> UsedUsed tank chart to find 95 % . Inspected Flapper valve at 95 % <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify) : <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages 6 <br /> TANK ID : (By tank number, stored product, etc.) Tank- 1 Diesel Tank-2 Diesel Tank-3 Diesel Tank-6 Auto Diesel <br /> What is the tank inside diameter? (Inches) 1173/4 of 1173/4 11 1173/4 it 1173/4 It <br /> Is the fill piping secondarily contained ? ❑ Yes ix No ❑ Yes ❑x No ❑ Yes E No <br /> El Yes ❑x No <br /> Is the vent piping secondarily contained ? ❑ Yes E No ❑ Yes ❑x Nox <br /> ❑ Yes ❑ No ❑ Yes 2 No <br /> Overfill Prevention Equipment Manufacturer(s) Phil-Tite Flapper OPW Flapper OPW Flapper Phil-Tite Flapper <br /> 95% 95% 95% 95% <br /> What is the overfill prevention equipment response x❑ Shuts Off Flow ❑x Shuts Off Flow x❑ Shuts Off Flow ❑x Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes 0 No ❑ Yes ❑x No ❑ Yes ❑x No <br /> El Yes Q No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 107 1 /2 " 1053/8 1053/8 1101 /4 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 96 . 24 % 94 . 99 % 94 . 99 % 97 . 86 % <br /> Is the overfill prevention in proper operating condition ❑ Yes 0 Yes ❑x Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? Q No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑ Pass ❑x Fail ❑x Pass ❑ Fail ❑x Pass ❑ Fail ❑ Pass ❑x Fail <br /> V. COMMENTS <br /> Any items marked "Fail" must be explained in this section . Any additional comments may also be provided here. <br /> Tank 1 Diesel truck side flapper is set to fully close at 96 . 24% and tank 6 Auto diesel flapper is set to fully close at 97 . 86 % <br /> per tank charts . Tank 2 and 3 Diesel truck side flapper are both set to fully close at 94 . 99% of total tank capacity per tank <br /> charts . <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16 , Section 2637 .2 and all the information contained herein is accurate . <br /> UST Service Technician Signature /> <br /> If the facility has more components than his form accommodates, additional copies of this page maybe attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Usual <br />
The URL can be used to link to this page
Your browser does not support the video tag.