Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page i of i) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection Q 36 Month Inspection <br /> L FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10182131 12/13/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Pilot Flying J 168 Ripon <br /> Business Site Address City ZIP Code <br /> 1501 N. Jack Tone Rd, Ripon 95366 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone# <br /> Jose Ochoa (888) 972-7581 <br /> Contractor 1 Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 804431 8004551-UT 12/27/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> OPW Cert# 100826 Expiration Date: 1-19-2020 <br /> Ili. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines{Specify}: <br /> Used: Used tank chart to find 95%. Inspected Flapper valve at 95% <br /> ❑Industry Code or Engineering Standard (Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages 6 <br /> TANK ID: (By tank number,stored product,etc.) Tank-8 Bio-Diesel Tank-4 87 Tank-5 91 <br /> What is the tank inside diameter?(Inches) 118 318" 117 314" 117 314" <br /> Is the fill piping secondarily contained? ❑x Yes ❑No ❑Yes 0 No ❑Yes ❑x No ❑Yes <br /> ❑Na <br /> Is the vent piping secondarily contained? ❑x Yes ❑ No ❑Yes ❑x No ❑Yes El No ❑Yes ❑No <br /> Overfill Prevention Equipment Manufacturers) OPW Flapper Phil-Tice Flapper Phil-Fite Flapper <br /> 95% 95% 95% <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow x❑Shuts Off Flow ❑x Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) EI Restricts Flow ❑ Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> ❑AIV Alarm ❑AIV Alarm ❑AIV Alarm ❑AN Alarm <br /> Are Flow restrictors installed on vent piping? ❑Yes E No ❑Yes N No ❑Yes ❑x No ❑Yes <br /> ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 109 314" 110" 108° <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 97% 96.74% 96.76% <br /> Is the overfill prevention in proper operating condition ❑Yes ❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? N No(Specify in V.) ❑x No(Specify in V.) I [E No(Specify in V.) ❑No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑ Pass ❑x Fail ❑Pass N Fail ❑Pass X Fail ❑Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail'most be explained in this section. Any additional comments may also be provided here. <br /> Tank#8 Bio-Diesel flapper is set at 97%, Tank#4 87 flapper is set at 96.74% and Tank#5 91flapper is set at 96.76%. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than Zisform accommodates,additional copies of this page maybe attached. <br /> CERS=California Environmental Reporting System.ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AIV=Audible and Usual <br />