My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 11:41:32 AM
Creation date
3/22/2019 8:06:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> SAN_ JOAQUIN AMi <br /> _ <br /> --COUNTY M lli, jlq <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#618* 1501 N JACK TONE RD, RIPON May 08, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for tank#7 is not current in CERS. In the tank forms for Tank#7 under overfill <br /> protection, it states"audible and visual" as the means of overfill however audible and visual means of overfill cannot <br /> be used as the only means of overfill in a new regulated UST without ball floats, or double wall vent line, and double <br /> wall riser pipe. Any change of information must be updated in CERS within 30 days of the changes. Immediately log <br /> into CERS, update the required information, and submit for review by the EHD. <br /> This is a repeat violation, Class Il. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. In the monitoring plan for tank#7 it states "no" <br /> under spill container testing, however based on the installation date of the tank (1994) "All underground storage <br /> tanks shall be equipped with a spill container that collects any hazardous substances spilled during product delivery <br /> operations to prevent the hazardous substance from entering the subsurface environment' and "Spill containers shall <br /> be tested for tightness at all of the following times: Upon the completion of an installation and every 12 months <br /> thereafter; and within 30 days of the date of the completion of a repair". In the monitoring plan for Tank#8 it states <br /> panel model#to be TLS 350, however TLS350 plus was observed during the field inspection. The monitoring plan <br /> must be uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br /> necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class Il. <br /> 118 CCR 2715(a)(1)(A), 2715(a)(2) Failure to submit the"Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> A CERS submittal uploaded on 2/20/19 was made with the "Designated Underground Storage Tank Operator <br /> Identification Form," however no "Underground Storage Tank Statement of Understanding and Compliance Form," <br /> was uploaded. "The owner or operator shall submit a signed "Underground Storage Tank Statement of <br /> Understanding and Compliance Form," upon any change in the owner or operator which previously submitted the <br /> signed "Underground Storage Tank Statement of Understanding and Compliance Form," no later than 30 days after <br /> the change. Since a "Designated Underground Storage Tank Operator Identification Form," has been uploaded after <br /> October 1st, 2018. It is required for the "Underground Storage Tank Statement of Understanding and Compliance <br /> Form," to be uploaded. Any changes shall be reported to the EHD within 30 days. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the "Underground Storage Tank <br /> Statement of Understanding and Compliance Form" for this facility. <br /> This is a minor violation. <br /> FA0006672 PR0505264 SCO01 05/08/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.